Installation Procedure for Cable Splice shield Kits for RG-Cables
RPIP-1108
Revision A
April, 2016
Devices Installation Procedure
© 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved. TE Proprietary & Confidential Information.
TUS-24-4006 rev E, 2 Aug 12
If this document is printed, it becomes uncontrolled. Check for latest revision.
Page 3 of 6
c.
Remove cable dielectric
leaving 2.5 mm (0.100’’)
exposed dielectric.
d.
Ensure exposed center conductor is 6.35 mm
(0.250’’
). Trim excess.
e.
Place the SolderSleeve onto the left cable end, with the small opening to
the left.
f.
Slide crimp barrel onto exposed center conductor. Ensure it is flush
against the cable dielectric. Crimp the metal barrel using the HX4
(M22520/5-01) crimp frame with the Y1535 crimp die.