background image

OPERATING INSTRUCTIONS

 

AST46DS

 

 

TE CONNECTIVITY SENSORS 

/// AST46DS OPERATING INSTRUCTIONS            

 

 03/2019

 

Page 2

 

WARNING & IMPORTANT SAFETY INSTRUCTIONS

 

This is the safety alert symbol. It is used to alert you to 

potential personal injury hazards. Obey all safety messages 

that follow this symbol to avoid possible injury or death.

 

DANGER

 indicates a hazardous situation which, if not avoided, 

 

will result in death or serious injury.

 

WARNING 

indicates a hazardous situation which, if not 

avoided, could result in death or serious injury.

 

CAUTION

 used with the safety alert symbol, indicates a 

hazardous situation which, if not avoided, could result in minor 

or moderate injury

.

 

 

 

ELECTRICAL INSTALLATION

 

 

EXPLOSION HAZARD

 

Do not install, repair or uninstall equipment unless power has been switched off and the area is known to be non-hazardous. 

This equipment must be powered by a Nonhazardous live source in accordance with CAN/CSA-C22.2 No. 61010-1-04 e.g. 

limited energy source, or a Class 2 Source.

 

Do not open when an explosive atmosphere may be present.

 

Please review the following wiring instructions. For U.S. installations, product case ground screw on the interior or exterior of 

the housing must be bonded to ground according to Article 501 & 505 of the NEC

 

Recommended Wire Gauge: 18-22 AWG

 

 

Remove rear cover by hand to access terminal blocks.

 

 

Run wire through conduit connection and feed toward terminal blocks. Conduit should be installed over wire / cable per 
electrical code requirements.

 

 

Use a Phillips-Head screw driver to loosen terminal screws

 

 

Connect wires to the proper terminal according to chart and tighten screw.

 

 

Ensure either the internal or external case ground screw is bonded to ground according to Article 501 & 505 of the NEC.

 

 

Install conduit plug if one side of electrical connection is unused.

 

 

Close cover

 

Field Service

 

The AST46DS has no field serviceable parts. For technical issues or questions, please contact the factory.

 

 

 