2.4.
Remove Contacts
The wire dress cover must be removed and the TPA must be moved to the open (unlocked) position
before
any
contacts can be removed.
1. From the mating face of the plug, insert the tip of a jewel
er’s screwdriver into the contact cavity of the
contact to be removed until it stops, then rotate the screwdriver toward the contact to deflect the
retention latch finger of the contact cavity.
2. Holding the screwdriver tool in place, gently pull the wire of the contact to be removed until the contact
is out of the housing. See Figure 8.
CAUTION
Take care not to damage the contacts during removal.
Figure 8
3.
REPLACEMENT AND REPAIR
Do not used damaged or defective product. The plug, wire dress cover, and contacts are not repairable. Do not
re-use contacts by removing the wire.
4.
REVISION SUMMARY
Initial release of instruction sheet