*) VR2020-LD only
USB (2x)
Deactivated by default. The USB ports are intended for future applications (e.g. for external
logging, UPS management).
Cellular MIMO
*)
SMA socket for the connection of the second antenna / second antenna cable
Cellular MAIN
*)
Connection for the primary antenna / first antenna cable. This connection is mandatory.
Power
Wide range voltage input 9V..30V DC with coaxial power connector.
Optionally available as clamping strip.
2.4
Initiation
Warning
➢
To prevent damage to the device or the SIM card, said card is only to be inserted or removed in a voltage-free
state!
Caution
➢
To prevent damage caused by condensation the router must be brought to room temperature before it is supplied
with voltage.
➢
Therefore, the router should be taken out of the packaging about one hour before initiation.
➢
In order to avoid damage to the device, handle with care.
1.
Carefully open the transport packaging.
2.
Take out the router by folding the cardboard flaps upwards and pulling out the device under the foil.
3.
Connect the necessary cables to the router, for example:
a.
Ethernet cable to the LAN-Port.
b.
Ethernet cable to the WAN-Port.
c.
TAE cable to the xDSL-socket.
d.
Antenna cables to the Cellular MAIN and MIMO
*)
.
4.
Only now connect the router to the power supply.
5.
As soon as the initiation process is completed the router can be reached via IP.
Caution
➢
It can take up to two minutes for the router to be reachable when booting the first time.
2.5
Login details and IP addresses
The VR2020-D and the VR2020-LD both have the IP address
192.168.0.50
by "factory default", additionally the user is
root
. The password is individually generated for each router during production process and printed on the nameplate.
Besides, IP addresses are also provided via DHCP in the standard configuration. Here the range is defined from
192.168.0.100
to
192.168.0.250
.
Parameter
Value
IP address
192.168.0.50
DNS name
tdt.router
Username
root
Password
Individually generated for each router (see nameplate).
Caution
➢
In the delivery state, the VR2020 has an individual password which can be found on the nameplate.
➢
Anyway, it is highly recommended to assign an individual password before starting a configuration!
➢
Before mounting the device, write down the password in order to retain access after a factory reset.