background image

7 CONNECTION 

TABLES 

7.1 

EXPERT AND EXCEL2 READER CONNECTIONS 

Controller 

Terminal 

Reader Connection 

Reader Wire Colour 

23 

Reader 1 IR Data 

Yellow 

26 

Reader 1 IR Source 

Blue 

27 Reader 

LED 

Green 
Red 
White 

28 

Reader 1 +5 V 

Black 

37 

Reader 2 IR Data 

Yellow 

40 

Reader 2 IR Source 

Blue 

41 Reader 

LED 

Green 
Red 
White 

42 

Reader 2 +5 V 

Black 

Table 1 – eXpert and eXcel

2

 to Microcard Reader 5002-0035 

 

Controller 

Terminal 

Reader Connection 

Reader Wire Colour 

24 Reader 

Data/D0 

Yellow 

25 Reader 

Clock/D1 

White 

27 Reader 

LED 

Blue 

29 Reader 

0V 

Black 

30 

Reader 1 +12 V 

30 

Reader 2 +12 V 

Red 

38 Reader 

Data/D0 

Yellow 

39 Reader 

Clock/D1 

White 

41 Reader 

LED 

Blue 

43 

Reader 2 0 V 

Black 

Table 2 – eXpert and eXcel

2

 to

 

eXprox 5002-035x and Optica 5002-039x 

 

Controller 

Terminal 

Reader Connection 

Reader Wire Colour 

24 Reader 

Data 

Yellow 

25 Reader 

Clock 

White 

27 Reader 

LED 

Blue 
Red 

28 

Reader 1 +5 V 

Green 

29 Reader 

0V 

Black 

38 Reader 

Data/D0 

Yellow 

39 Reader 

Clock/D1 

White 

41 Reader 

LED 

Blue 
Red 

42 

Reader 2 +5 V 

Green 

43 

Reader 2 0 V 

Black 

Table 3 – eXpert and eXcel

2

 to

 

Magnetic Swipe Reader 5002-0360 

 
 

7.2 

EXCEL2 DOOR FURNITURE CONNECTIONS 

Controller Terminal 

Equipment Connection 

18 

Door 1 lock relay pole 

19 

Door 1 lock relay n/o 

32 

Door 2 lock relay pole 

33 

Door 2 lock relay n/o 

Table 4 - eXpert and eXcel

connections to lock (fail-locked condition) 

 

Controller Terminal 

Equipment Connection 

17 

Door 1 lock relay n/c 

18 

Door 1 lock relay pole 

31 

Door 2 lock relay n/c 

32 

Door 2 lock relay pole 

Table 5 - eXpert and eXcel

connections to lock (fail-open condition) 

 

Controller Terminal 

Equipment Connection 

2+ 

Door lock Supply (1 A max.) 

2- 

Door lock 0 V 

3+ 

Door lock Supply (1 A max.) 

3- 

Door lock 0 V 

Table 6 - eXpert and eXcel

connections for power supply for locks 

 

Controller Terminal 

Equipment Connection 

20 

Door 1 door sense input 

21 

Door 1 door sense 0 V 

34 

Door 2 door sense input 

35 

Door 2 door sense 0 V 

Table 7 - eXpert and eXcel

2

 connections for door sensors 

 

Controller Terminal 

Equipment Connection 

21 

Door 1 door egress 0 V 

22 

Door 1 door egress input 

35 

Door 2 door egress 0 V 

36 

Door 2 door egress input 

Table 8 - eXpert and eXcel

2

 connections for egress buttons 

 
 

7.3 

EXCEL2 INPUT AND RELAY CONNECTIONS 

Controller Terminal 

Equipment Connection 

34 Input 

35 

0 V (for inputs 3 & 4) 

36 Input 

50 Input 

51 

0 V (for inputs 5 & 6) 

52 Input 

53 Input 

54 

0 V (for inputs 7 & 8) 

55 Input 

Table 9 – eXpert and eXcel

2

 Input Connections 

 

Controller Terminal 

Equipment Connection 

31 Relay 

n/c 

32 Relay 

pole 

33 Relay 

n/o 

44 Relay 

n/c 

45 Relay 

pole 

46 Relay 

n/o 

47 Relay 

n/c 

48 Relay 

pole 

49 Relay 

n/o 

Table 10 – eXpert and eXcel

Relay Connections 

 

7.4 EXCEL2 

COMMUNICATIONS 

CONNECTIONS 

PC 9-way 

PC 25-way 

Controller 
Terminal 

Function 

2 3 7  Receive 

Data 

(Rx) 

3 2 6  Transmit 

Data 

(Tx) 

5 7 5  Ground 

Table 11 - eXpert and eXcel

RS-232 Connections (Direct Communications) 

 

IP Connected Controller 

RS-485 

Connected 

Controller 

Function 

1 1 

RS-485 

Rx 

2 2 

RS-485 

Rx 

3 3 

RS-485 

Tx 

4 4 

RS-485 

Tx 

Controller Chassis 

Controller Chassis 

Cable Screen 

Table 12 - Connection when using an IP Enabled Controller as an Ethernet Converter 

 

For communications using a separate serial to Ethernet converter or serial to RS-485 
converter, please refer to the documentation supplied with those devices. 

7.5 EXCEL4 

READER 

CONNECTIONS 

Controller 

Terminal 

Reader Connection 

Reader Wire Colour 

14 Reader 

Data/D0 

Yellow 

15 Reader 

Clock/D1 

White 

16 Reader 

LED 

Blue 

17 

Reader 1 +12 V 

Red 

18 Reader 

0V 

Black 

25 Reader 

Data/D0 

Yellow 

26 Reader 

Clock/D1 

White 

27 Reader 

LED 

Blue 

28 

Reader 2 +12 V 

Red 

29 

Reader 2 0 V 

Black 

30 Reader 

Data/D0 

Yellow 

31 Reader 

Clock/D1 

White 

32 Reader 

LED 

Blue 

28 

Reader 3 +12 V 

Red 

29 

Reader 3 0 V 

Black 

41 Reader 

Data/D0 

Yellow 

42 Reader 

Clock/D1 

White 

43 Reader 

LED 

Blue 

44 

Reader 4 +12 V 

Red 

45 

Reader 4 0 V 

Black 

Table 13 – eXcel

4

 to

  

eXprox 5002-035x, Optica 5002-039x and Digital IR 5002-1781  

 

Controller 

Terminal 

Reader Connection 

Reader Wire Colour 

14 Reader 

Data/D0 

Yellow 

15 Reader 

Clock/D1 

White 

16 Reader 

LED 

Blue 

12 

Reader 1 +5 V 

Red 

18 Reader 

0V 

Black 

25 Reader 

Data/D0 

Yellow 

26 Reader 

Clock/D1 

White 

27 Reader 

LED 

Blue 

39 

Reader 2 +5 V 

Red 

29 

Reader 2 0 V 

Black 

30 Reader 

Data/D0 

Yellow 

31 Reader 

Clock/D1 

White 

32 Reader 

LED 

Blue 

39 

Reader 3 +5 V 

Red 

29 

Reader 3 0 V 

Black 

41 Reader 

Data/D0 

Yellow 

42 Reader 

Clock/D1 

White 

43 Reader 

LED 

Blue 

40 

Reader 4 +5 V 

Red 

45 

Reader 4 0 V 

Black 

Table 14 – eXcel

4

 to

 

Magnetic Swipe Reader 5002-0360 

7.6 

EXCEL4 DOOR FURNITURE CONNECTIONS 

Controller Terminal 

Equipment Connection 

20 

Door 1 lock relay pole 

21 

Door 1 lock relay n/o 

34 

Door 2 lock relay pole 

35 

Door 2 lock relay n/o 

47 

Door 3 lock relay pole 

48 

Door 3 lock relay n/o 

53 

Door 4 lock relay pole 

54 

Door 4 lock relay n/o 

Table 15 – eXcel

connections to lock (fail-locked condition) 

 

Controller Terminal 

Equipment Connection 

19 

Door 1 lock relay n/c 

20 

Door 1 lock relay pole 

33 

Door 2 lock relay n/c 

34 

Door 2 lock relay pole 

46 

Door 3 lock relay n/c 

47 

Door 3 lock relay pole 

52 

Door 4 lock relay n/c 

53 

Door 4 lock relay pole 

Table 16 – eXcel

connections to lock (fail-open condition) 

 

Controller Terminal 

Equipment Connection 

2+ 

Door lock Supply (1 A max.) 

2- 

Door lock 0 V 

3+ 

Door lock Supply (1 A max.) 

3- 

Door lock 0 V 

Table 17 – eXcel

connections for power supply for locks 

 

Controller Terminal 

Equipment Connection 

22 

Door 1 door sense input 

23 

Door 1 door sense 0 V 

36 

Door 2 door sense input 

37 

Door 2 door sense 0 V 

49 

Door 3 door sense input 

50 

Door 3 door sense 0 V 

55 

Door 4 door sense input 

56 

Door 4 door sense 0 V 

Table 18 – eXcel

4

 connections for door sensors 

 

 

 
 

Table 19 – eXcel

4

 connections for egress buttons 

7.7 

EXCEL4 COMMUNICATIONS CONNECTIONS 

PC 9-way 

PC 25-way 

Controller Terminal 

Function 

2 3  7 

Receive 

Data 

(Rx) 

Transmit Data (Tx) 

5 7  5 

Ground 

Table 20 – eXcel

RS-232 Connections (Direct Communications) 

 

Controller Terminal 

Equipment Connection 

23 

Door 1 door egress 0 V 

24 

Door 1 door egress input 

37 

Door 2 door egress 0 V 

38 

Door 2 door egress input 

50 

Door 3 door egress 0 V 

51 

Door 3 door egress input 

56 

Door 4 door egress 0 V 

57 

Door 4 door egress input 

TECHNICAL SPECIFICATION – POWER SUPPLY 

 

Input Voltage 

230 Vac n10 %/-15 % 

Input Frequency 

50 Hz 

Mains Input Fuse 

T2A 20 mm 230 v HRC 

Output Voltage 

13.6 to 14.0 VDC on mains power 
10.5 to 12.3 VDC on battery standby 

Output Load Current 

3 A 

Output Ripple 

50 mV

p-p

 max @ 230 V ±10 % 

600 mV

p-p 

max @ 230 V -15% 

Output Load Regulation 

5 % 

Load Output Fuse 

F3.15 A 20 mm 

Overload Protection 

Electronic shutdown until overload/short circuit removed 

Standby Battery 
Capacity/Recharge Time 

1 x 7 Ah Sealed Lead Acid/13 hours (to 80% capacity) 

Standby Battery Charge 
Current 

0.5 A 

Standby Battery Fuse 
Protection 

F3.15 A 20 mm 

Green LED 

Mains present 

Red LED 

Fault present: output fuse fail 

Visual Indications 

Amber LED 

Battery Standby operation 

Storage Temperature Range 

-20 °C to +80 °C 

Operating Temperature Range 

-5 °C to + 45 °C 

Operating Humidity 

<95 %RH, non-condensing 

 

 