Polycom
®
VVX
®
Series
Expansion Module Administrator Guide
166015/6-15/9072
To enable Custom Configuration 1:
1. Log in to the
managed
IP Administrator web portal and navigate to the user with the expansion module(s).
2. Enable Expansion Module Templates by using the “Modify Tags” function. Change the value of
%EXP_MOD_TEMPLATES_ENABLED%
to “1” (on) to activate.
3. Rebuild the device.
4. Reset the device.
NOTE: Please refer to the
managed
IP Administrator User Guide for more detailed instructions on the
“Modify Tags” function.
Custom Configuration 2 – Mini-console with 2 or 3 EMs
This configuration is ideal for an answering position (“mini-console”) with two or more EM’s that uses Status
Connect to monitor other users. With this configuration, Status Connect keys appear on page 1 of both the first
and second EM’s.
This eliminates the need for a busy answering position monitoring more than 28 Status Connect users to toggle
between pages one and two of the first EM. By selecting page 1 of both EM 1 and EM 2, all Status Connect
users are visible with a single glance, providing greater efficiency for the user. See the Appendix -
Custom
Configuration 2
, for specific key assignment.
To enable Custom Configuration 2:
1. Log in to the managedIP Administrator web portal and navigate to the user with the expansion module(s).
2. Using the “Modify Tags” function:
a. Enable Expansion Module Templates by changing the value of
%EXP_MOD_TEMPLATES_ENABLED%
to “1” (on).
b. Enable the Status Connect View by changing the value of
%EXP_MOD_STATUS_CONNECT_VIEW%
to “Unassigned”.
3. Rebuild the device.
4. Reset the device.
NOTE: With the EM custom configurations, specify the exact key a Speed Dial Favorite should appear
on by setting the Favorite Index to the value noted on the template. Please refer to the Polycom Detailed
Guide, “Managing Favorites” for further detail on programming Favorites and changing indices.