(14/30)
004-02 / 20070523 / ea122_jbw.fm
• All specifications are subject to change without notice.
JBW150W Type
SPECIFICATIONS AND STANDARDS
∗
Current rating(maximum output current) is determined for –10 to +40°C. Derating is required when used outside this temperature range.
Part No.
JBW05-30R
JBW12-12R
JBW15-10R
JBW24-6R3
JBW48-3R2
Rated output voltage and current
∗
5V • 30A
12V • 12A
15V • 10A
24V • 6.3A
48V • 3.2A
Maximum output power
W
150
150
150
151.2
153.6
Input conditions
Input voltage Eac/Edc
V
85 to 265[Rating: 100-240]/120 to 370
Input frequency
Hz
47 to 66
Input current
A
2.7/1.5max.[100-240V]
Surge current
A
30/60max.[100-240V]
Leakage current
mA
0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
Power factor
0.99/0.95typ.[100-240V]
Efficiency
%
78/80typ.
[100-240V]
81/83typ.
[100-240V]
81/83typ.
[100-240V]
82/84typ.
[100-240V]
82/84typ.
[100-240V]
Output characteristics
Output voltage Edc
V
5
12
15
24
48
Voltage variable range Edc
V
4.5 to 5.5
10.8 to 13.2
13.5 to 16.5
21.6 to 26.4
43.2 to 52.8
Maximum output current
A
30
12.5
10
6.3(Peak7.5)
3.2
Overvoltage threshold Edc
V
5.75 to 6.9
13.8 to 16.8
17.2 to 21
27.6 to 33.6
55.2 to 67.2
Overcurrent threshold
A
31.5min.
15.7min.
12.5min.
7.87min.
3.36min.
Voltage
stability
Source effect
%
0.4max.[Within the input voltage range]
Load effect
%
0.8max.[0 to 100% load]
Temperature effect
%
1max.[Ambient temperature: –10 to +60°C]
Drift(Time effect)
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%
±4max.[50 to 100% sudden load change]
Ripple Ep-p
mV
80max.
120max.
120max.
120max.
150max.
Ripple noise Ep-p
mV
120max.
150max.
150max.
150max.
350max.
Start up time
ms
500max.(400typ.)/500max.(300typ.)[AC.100/240V]
Hold up time
ms
25/35typ.[AC.100/240V]
Auxiliary functions
Indicator display
No
Overvoltage protection
Voltage shut-down type(Latch).
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Standards
Safety standards
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
Noise terminal voltage
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
Input harmonics current requirement
EN61000-3-2
CE marking
Meet.
Constructions
External dimensions
mm
40
×
75
×
222[H
×
W
×
L]
Weight
g
550max.
Mounting method
Can be attached to 1 side.
Case metal
FR4