![TDK J Series JBW Specification Sheet Download Page 12](http://html1.mh-extra.com/html/tdk/j-series-jbw/j-series-jbw_specification-sheet_3996832012.webp)
(12/30)
004-02 / 20070523 / ea122_jbw.fm
• All specifications are subject to change without notice.
JBW100W Type
SPECIFICATIONS AND STANDARDS
Part No.
JBW05-20R
JBW12-8R5
JBW15-6R7
JBW24-4R3
Rated output voltage and current
5V • 20A
12V • 8.5A
15V • 6.7A
24V • 4.3A
Maximum output power
W
100
102
100.5
103.2
Input conditions
Input voltage Eac/Edc
V
85 to 265[Rating: 100-240]/120 to 370
Input frequency
Hz
47 to 66
Input current
A
1.8/1.0max.[100-240V]
Fuse rating
A
5
Surge current
A
30/60max.[100-240V]
Leakage current
mA
0.75/0.75max.[AC.100V(DENAN)/240V(UL, IEC)]
Power factor
0.99/0.95typ.[100-240V]
Efficiency
%
78/80typ.
[100-240V]
80/82typ.
[100-240V]
80/82typ.
[100-240V]
82/85typ.
[100-240V]
Output characteristics
Output voltage Edc
V
5
12
15
24
Voltage variable range Edc
V
±10%
±10%
±10%
±10%
Maximum output current
A
20
8.5
6.7
4.3(Peak5)
Overvoltage threshold Edc
V
5.75 to 6.9
13.8 to 16.8
17.2 to 21
27.6 to 33.6
Overcurrent threshold
A
21.0min.
10.6min.
8.38min.
5.38min.
Voltage
stability
Source effect
%
0.4max.[Within the input voltage range]
Load effect
%
0.8max.[0 to 100% load]
Temperature effect
%
1max.[Ambient temperature: –10 to +60°C]
Drift(Time effect)
%
0.4max.[25°C, input and output ratings, after input voltage ON for 30min to 8h]
Recovery
%
±4max.[50 to 100% sudden load change]
Ripple Ep-p
mV
80
120
120
120
Ripple noise Ep-p
mV
120
150
150
150
Start up time
ms
500max.(400typ.)/500max.(300typ.)[AC.100/240V]
Hold up time
ms
20typ.[100-240V]
Auxiliary functions
Indicator display
No
Overvoltage protection
Voltage shut-down type(Latch).
Overcurrent protection
Rectangular type, automatic recovery.
Remote ON-OFF
No
Remote sensing
No
Standards
Safety standards
UL60950-1, CSA C22.2 No.60950-1(C-UL), EN60950-1(TÜV) approved.
Noise terminal voltage
FCC-B, VCCI-B, EN55011-B, EN55022-B meet.
Input harmonics current requirement
EN61000-3-2
CE marking
Planned compliance.
Constructions
External dimensions
mm
35
×
62
×
222[H
×
W
×
L]
Weight
g
400max.
Mounting method
Can be attached to 1 side.
Case material
FR4