TDK FReta iEB Series Datasheet Download Page 6

                                                                                                                        

 

 

 

Advance Data Sheet: FReta iEB Series –Single Output Eighth Brick Bus Converter

 

©2004-2007  TDK Innoveta Inc.  
 10/29/2007 

 

 (877) 498-0099

 

6/12 

 

 

Electrical Characteristics:

 

iEB48017A120V-000 through -007: 12V, 17A Output 

90

91

92

93

94

95

96

0

2

4

6

8

10

12

14

16

18

20

Output Current (A)

E

ff

ic

ie

n

c

y

ηηηη

(%

)

Vin = 38V

Vin = 48V

Vin = 53V

 

0

2

4

6

8

10

12

14

0

2

4

6

8

10

12

14

16

18

20

Output Current (A)

P

o

w

e

D

is

s

ip

a

ti

o

n

 (

W

)

Vin = 38V

Vin = 48V

Vin = 53V

 

iEB48017A120V-000 Typical Efficiency vs. Input 
Voltage at Ta=25 degrees. 

iEB48017A120V-000 Typical Power Dissipation vs. 
Input Voltage at Ta=25 degrees 

8

9

10

11

12

13

14

0

2

4

6

8

10

12

14

16

18

20

Output Current (A)

O

u

tp

u

V

o

lt

a

g

e

 (

V

)

Vin = 38V

Vin = 48V

Vin = 53V

Vin = 42V

 

 

iEB48017A120V-000 Typical Output Voltage vs. Load 
Current at Ta = 25 degrees 

iEB48017A120V-001 Typical startup characteristic from 
on/off at full load, 1mS/div.  Lower trace - on/off signal 
2V/div, upper trace – output voltage 5V/div.

 

 

 

 iEB48017A120V-000 Typical startup characteristic 
from input voltage application at full load, 1mS/div.  
Lower trace - input voltage 20V/div, Upper trace – 
output voltage 5V/div  

iEB48017A120V-000 Typical transient response 
10uS/div. Output voltage response to load step from 
0% to 100% of full load with output current slew rate of 
1A/uS, Upper trace – output voltage 1V/div.  

Summary of Contents for FReta iEB Series

Page 1: ...converters Standard Features Size 58 4mm x 22 9 mm x 12 3 mm 2 30 in x 0 90 in x 0 485 in Long Thru hole pins 4 57 mm 0 180 High efficiency greater than 94 2250Vdc isolation voltage Meets basic insula...

Page 2: ...nnoveta Eighth brick FReta 48V nominal 017 17A Amps 120 12V Single 07 Standard Option Table Feature Set Positive Logic On Off Negative Logic On Off 0 180 Pin Length 0 145 Pin Length 00 X X 01 X X 06 X...

Page 3: ...99 3 12 Mechanical Specification Dimensions are in mm in Unless otherwise specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Recommended Hole Pattern top view Pin Assignment PIN FUNCTION...

Page 4: ...Io Io max Tc 25 C Output Voltage Rise Time 4 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Input Over voltage Turn off 61 Vdc Input rising Input Over voltage Turn on 59 Vdc Input falling Input Over volta...

Page 5: ...ax Io Io min Vin Vin min 19 5 Vin Vin nom 17 Output Current Vin Vin max 1 16 A At loads less than Io min the module will operate correctly but the output ripple may increase Output Current Limiting Th...

Page 6: ...vs Input Voltage at Ta 25 degrees 8 9 10 11 12 13 14 0 2 4 6 8 10 12 14 16 18 20 Output Current A Output Voltage V Vin 38V Vin 48V Vin 53V Vin 42V iEB48017A120V 000 Typical Output Voltage vs Load Curr...

Page 7: ...Output Current Limit Characteristics vs Input Voltage at Ta 25 degrees iEB48017A120V 000 Typical Output Ripple at nominal Input voltage and full load at Ta 25 degrees 0 1 2 3 4 5 6 31 33 35 37 39 41 4...

Page 8: ...flow from output to input 0 7 0 8 0 9 1 0 1 1 1 2 1 3 35 40 45 50 55 60 Input Voltage V Derating Factor iEB48017A120V 000 thermal measurement location top view iEB48017A120V 000 typical current derati...

Page 9: ...in most modern electronic systems with distributed power architectures The electronic equipment in networking telecom wireless and advanced computer systems operates in similar environments and utiliz...

Page 10: ...es may protect themselves by entering a hiccup current limit mode The modules will operate normally once the output current returns to the specified operating range Thermal Protection When the power m...

Page 11: ...od Improper handling or cleaning processes can adversely affect the appearance testability and reliability of the power modules Contact TDK Innoveta technical support for guidance regarding proper han...

Page 12: ...met 1 The input source is isolated from the ac mains by reinforced insulation 2 The input terminal pins are not accessible 3 One pole of the input and one pole of the output are grounded or both are k...