Absolute Maximum Ratings: 

Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device

 

*Engineering estimation 

 
 
 

 
Input Characteristics: 

 

Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions. 

Characteristic 

Min 

Typ 

Max 

Unit 

Notes & Conditions 

Operating Input Voltage 

38 

48 

53 

Vdc 

 

Maximum Input Current 

--- 

--- 

6.5* 

Vin = 0 to Vin,max 

Turn-on Voltage 

--- 

36 

--- 

Vdc 

 

Turn-off Voltage 

31* 

34.5 

--- 

Vdc 

 

Hysteresis 

0.5* 

1.5 

--- 

Vdc 

 

Startup Delay Time from application of input 
voltage  

--- 

--- 

mS 

Vo = 0 to 0.1*Vo,nom;

 

on/off =on, 

Io=Io,max, Tc=25˚C 

Startup Delay Time from on/off  

--- 

--- 

mS 

Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom, 
Io=Io,max,Tc=25˚C  

Output Voltage Rise Time  

--- 

--- 

mS 

Io=Io,max,Tc=25˚C, Vo=0.1 to 0.9*Vo,nom 

Input Over-voltage Turn-off  

--- 

61 

--- 

Vdc 

Input rising 

Input Over-voltage Turn-on 

--- 

59 

--- 

Vdc 

Input falling 

Input Over-voltage Hysteresis 

--- 

--- 

Vdc 

 

Inrush Transient 

--- 

--- 

0.2 

A

2

 

Input Reflected Ripple  

--- 

50 

--- 

mApp 

See input/output ripple and noise 
measurements figure; BW = 20 MHz 

*Engineering estimation 
 

Caution: The power modules are not internally fused.  An external input line normal blow fuse with a maximum value of 
10A is required; see the Safety Considerations section of the data sheet. 

 

 

Characteristic 

Min 

Max 

Unit 

Notes & Conditions 

Continuous Input Voltage 

-0.5 

75 

Vdc 

 

Transient Input Voltage  

--- 

--- 

Vdc 

 

Isolation Voltage 

--- 

2250 

Vdc 

Basic insulation 

Storage Temperature 

-55 

125 

˚C 

 

Operating Temperature Range (Tc) 

 
 

-40 

123* 

˚C 

Measured at the location specified in the thermal 
measurement figure.  Maximum temperature varies 
with model number, output current, and module 
orientation – see curve in thermal performance 
section of the data sheet. 

Summary of Contents for FReta iEB Series

Page 1: ...converters Standard Features Size 58 4mm x 22 9 mm x 12 3 mm 2 30 in x 0 90 in x 0 485 in Long Thru hole pins 4 57 mm 0 180 High efficiency greater than 94 2250Vdc isolation voltage Meets basic insula...

Page 2: ...nnoveta Eighth brick FReta 48V nominal 017 17A Amps 120 12V Single 07 Standard Option Table Feature Set Positive Logic On Off Negative Logic On Off 0 180 Pin Length 0 145 Pin Length 00 X X 01 X X 06 X...

Page 3: ...99 3 12 Mechanical Specification Dimensions are in mm in Unless otherwise specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Recommended Hole Pattern top view Pin Assignment PIN FUNCTION...

Page 4: ...Io Io max Tc 25 C Output Voltage Rise Time 4 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Input Over voltage Turn off 61 Vdc Input rising Input Over voltage Turn on 59 Vdc Input falling Input Over volta...

Page 5: ...ax Io Io min Vin Vin min 19 5 Vin Vin nom 17 Output Current Vin Vin max 1 16 A At loads less than Io min the module will operate correctly but the output ripple may increase Output Current Limiting Th...

Page 6: ...vs Input Voltage at Ta 25 degrees 8 9 10 11 12 13 14 0 2 4 6 8 10 12 14 16 18 20 Output Current A Output Voltage V Vin 38V Vin 48V Vin 53V Vin 42V iEB48017A120V 000 Typical Output Voltage vs Load Curr...

Page 7: ...Output Current Limit Characteristics vs Input Voltage at Ta 25 degrees iEB48017A120V 000 Typical Output Ripple at nominal Input voltage and full load at Ta 25 degrees 0 1 2 3 4 5 6 31 33 35 37 39 41 4...

Page 8: ...flow from output to input 0 7 0 8 0 9 1 0 1 1 1 2 1 3 35 40 45 50 55 60 Input Voltage V Derating Factor iEB48017A120V 000 thermal measurement location top view iEB48017A120V 000 typical current derati...

Page 9: ...in most modern electronic systems with distributed power architectures The electronic equipment in networking telecom wireless and advanced computer systems operates in similar environments and utiliz...

Page 10: ...es may protect themselves by entering a hiccup current limit mode The modules will operate normally once the output current returns to the specified operating range Thermal Protection When the power m...

Page 11: ...od Improper handling or cleaning processes can adversely affect the appearance testability and reliability of the power modules Contact TDK Innoveta technical support for guidance regarding proper han...

Page 12: ...met 1 The input source is isolated from the ac mains by reinforced insulation 2 The input terminal pins are not accessible 3 One pole of the input and one pole of the output are grounded or both are k...

Reviews: