TDK FReta iEB Series Datasheet Download Page 1

                                                                                                                        

 

 

 

Advance Data Sheet: FReta iEB Series –Single Output Eighth Brick Bus Converter

 

©2004-2007  TDK Innoveta Inc.  
 10/29/2007 

 

 (877) 498-0099

 

1/12 

 

 

 

 

 

 

 

    
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
The FReta Series offers an 

industry 

standard 200W Eighth brick

 power module 

featuring a 

high operating efficiency

 that 

results in true useable power.  The FReta 
modules offer a fixed conversion ratio of 4:1.  
The unregulated power train topology 
provides a low cost, high performance, high 
reliability solution that is suitable for 
distributed power architectures that utilize an 
intermediate voltage bus to power non-
isolated point of load converters.  

 
 Standard Features: 
 

 
 

 

Size – 58.4mm x 22.9 mm x 12.3 
mm (2.30 in. x 0.90 in. x 0.485 in.) 

 

Long Thru-hole pins 4.57 mm 
(0.180”) 

 

High efficiency – greater than 94%  

 

2250Vdc isolation voltage 

 

Meets basic insulation spacing 
requirements 

 

Constant switching frequency 

 

Industry Standard Footprint 

 

Remote on/off (negative logic) 

 

Auto-recovering input over-voltage 
protection 

 

Auto-recovering output over-
current protection 

 

Auto-recovering output short circuit 
protection 

 

Auto-recovering over-temperature 
protection 

 

Applying for UL 60950 (U.S. and 
Canada), VDE 0805, CB scheme 
(IEC950), CE Mark (EN60950)  

 

ISO Certified manufacturing 
facilities 

 
Optional Features: 

 

 

Remote on/off (positive logic) 

 

Short Thru-hole pins 3.68 mm 
(0.145”) 

 
 
 

 

 
 
 
 
 
 
 
 

 
 

FReta iEB Series DC/DC Power Modules

  

48V Input, 200W Output  

Eighth Brick

 

Summary of Contents for FReta iEB Series

Page 1: ...converters Standard Features Size 58 4mm x 22 9 mm x 12 3 mm 2 30 in x 0 90 in x 0 485 in Long Thru hole pins 4 57 mm 0 180 High efficiency greater than 94 2250Vdc isolation voltage Meets basic insula...

Page 2: ...nnoveta Eighth brick FReta 48V nominal 017 17A Amps 120 12V Single 07 Standard Option Table Feature Set Positive Logic On Off Negative Logic On Off 0 180 Pin Length 0 145 Pin Length 00 X X 01 X X 06 X...

Page 3: ...99 3 12 Mechanical Specification Dimensions are in mm in Unless otherwise specified tolerances are x x 0 5 0 02 x xx and x xxx 0 25 0 010 Recommended Hole Pattern top view Pin Assignment PIN FUNCTION...

Page 4: ...Io Io max Tc 25 C Output Voltage Rise Time 4 mS Io Io max Tc 25 C Vo 0 1 to 0 9 Vo nom Input Over voltage Turn off 61 Vdc Input rising Input Over voltage Turn on 59 Vdc Input falling Input Over volta...

Page 5: ...ax Io Io min Vin Vin min 19 5 Vin Vin nom 17 Output Current Vin Vin max 1 16 A At loads less than Io min the module will operate correctly but the output ripple may increase Output Current Limiting Th...

Page 6: ...vs Input Voltage at Ta 25 degrees 8 9 10 11 12 13 14 0 2 4 6 8 10 12 14 16 18 20 Output Current A Output Voltage V Vin 38V Vin 48V Vin 53V Vin 42V iEB48017A120V 000 Typical Output Voltage vs Load Curr...

Page 7: ...Output Current Limit Characteristics vs Input Voltage at Ta 25 degrees iEB48017A120V 000 Typical Output Ripple at nominal Input voltage and full load at Ta 25 degrees 0 1 2 3 4 5 6 31 33 35 37 39 41 4...

Page 8: ...flow from output to input 0 7 0 8 0 9 1 0 1 1 1 2 1 3 35 40 45 50 55 60 Input Voltage V Derating Factor iEB48017A120V 000 thermal measurement location top view iEB48017A120V 000 typical current derati...

Page 9: ...in most modern electronic systems with distributed power architectures The electronic equipment in networking telecom wireless and advanced computer systems operates in similar environments and utiliz...

Page 10: ...es may protect themselves by entering a hiccup current limit mode The modules will operate normally once the output current returns to the specified operating range Thermal Protection When the power m...

Page 11: ...od Improper handling or cleaning processes can adversely affect the appearance testability and reliability of the power modules Contact TDK Innoveta technical support for guidance regarding proper han...

Page 12: ...met 1 The input source is isolated from the ac mains by reinforced insulation 2 The input terminal pins are not accessible 3 One pole of the input and one pole of the output are grounded or both are k...