INSTRUCTION MANUAL

ZBM-AC Series

TDK-Lambda

<Page>

2.  Model name identification method

  ZBM-AC162 /

 

Option (*1)

 

Bulk electrolytic capacitors capacity 

162

1680

μ

F

 

Series Name

 

3.  Terminal Explanation

1 +

: +Input/Buffer output terminal

2

: -Input/Buffer output terminal

3 Earth mounting hole (hole diameter : φ3.5mm)

   

Must be connected to Chassis (Conductor) of the equipment by electrically conductive spacer.

4 Mounting hole (hole diameter : φ3.5mm)
5 +/-RS

: +/- Ready Signal

6 +/-STB

: +/- STBY (Standby output voltage) (Option model "/S")

7 Red LED

: Bulk electrolytic capacitors voltage monitoring indicator 

 

  LED is off when bulk electrolytic capacitor is less than 60V.

8 Green LED

: Standby output monitoring indicator (Option model "/S")

5/12

*1

Blank

: Standard

/S

: Standby power supply model

1

2

3

4

5
6

7

8

1

2

3

4

Summary of Contents for ZBM-AC Series

Page 1: ...emission of smoke or abnormal smell and sound etc Please stop using it immediately and shut off the product It might lead to fire and electric shock In such cases please contact us Do not attempt rep...

Page 2: ...hydrogen sulfide sulfur dioxide etc there is possibility that they might penetrate the product and lead to failure When used in environments where there is conductive foreign matter or dust there is p...

Page 3: ...ss applied directly to the product Please keep away from direct sunlight For long term storage temperature and humidity the following conditions shall be used as a guideline Temperature range 5 30 Hum...

Page 4: ...ed failure risk by foreign material Safety standard certification IEC UL EN CSA 62368 1 IEC EN62477 1 OVC Support hold up time for SEMI F47 1 3 Applications Applications Usage FA Robot controller Secu...

Page 5: ...e diameter 3 5mm Must be connected to Chassis Conductor of the equipment by electrically conductive spacer 4 Mounting hole hole diameter 3 5mm 5 RS Ready Signal 6 STB STBY Standby output voltage Optio...

Page 6: ...Sensing Photo coupler Photo coupler RS RS Signal Circuit Bulk Capacitors Rectifier Filter Circuit Switching Circuit Control Circuit STB STB STBY output Input Buffer output Option model S Input Voltag...

Page 7: ...ction 6 1 below 6 1 Wiring for power supply and buffer module For the harness that connects the power supply and this product it is necessary to use harness with withstand voltage of 400V or higher eq...

Page 8: ...of the standby power supply for signals is 24Vtyp 22 8V 25 2V and the maximum output current is 0 2A The ground of the standby power supply terminal for signals is the STB terminal The STB terminal is...

Page 9: ...een signal and terminal each for 1 minute When testing withstand voltage set current limit of withstand voltage test equipment at 10mA Signal terminal 20mA The applied voltage must be gradually increa...

Page 10: ...Insert the spacer Max 8 of height more than 8mm to lift the product And use all mounting holes for the product installation 1 Mounting Holes size 4 holes 3 5mm Allowable area by metal pieces is 9mm fr...

Page 11: ...unting holes for Chassis connection is shown with mark in below figure 9 Wiring Method 1 The input buffer output load line and signal line shall be separated and use all lines as thick and short as po...

Page 12: ...rect 3 Check if the wire size is not too thin 4 Check if the output current and output power does not over specifications Option model S 5 Audible noise can be heard during Dynamic Load operation Opti...

Reviews: