PAQ
B-226
・All specifications are subject to change without notice.
PAQ50S48
PAQ50S48-* Specifications
PAQ
50S48
(*1) At 48VDC, maximum output current, air velocity = 2m/s and Ta = +25
℃
.
(*2) 36 - 76VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting. (The unit automatically shutdown when left in OCP condition
with the output voltage less than the LVP level.) Auto restart option available.
(*5) Inverter shutdown method, manual reset. Auto restart option available.
(*6) Refer to Instruction manual.
(*7) Refer to derating curve and instruction manual.
(*8) External components are needed for operation. (Refer to basic connection and Instruction manual.)
ITEMS/UNITS
MODEL PAQ50S48-1R2 PAQ50S48-1R8 PAQ50S48-2R5 PAQ50S48-3R3 PAQ50S48-5
Input
Voltage Range
V
DC36 - 76
Efficiency (typ)
(*1)
%
78
83
85
88
90
Current (typ)
(*1)
A
0.39
0.56
0.75
0.96
1.18
Output
Nominal Voltage
VDC
1.2
1.8
2.5
3.3
5
Maximum Current
A
12
10
Maximum Power
W
14.4
21.6
30
39.6
50
Voltage Setting Accuracy
(*1)
%
±
1
Maximum Line Regulation
(*2) mV
10
Maximum Load Regulation
(*3) mV
10
Temperature Coefficient
Less than 0.02%/
℃
Maximum Ripple & Noise
(*8) mVp-p
100
Voltage Adjustable Range
(*8)
-20%, +10%
±
15%
Function
Over Current Protection
(*4)
105% - 150% (Option availavle : Refer to option table)
Over Voltage Protection
(*5)
120% - 140% (Option availavle : Refer to option table)
Remote Sensing
(*6)
Possible
Remote ON/OFF Control
Possible (Option availavle : Refer to option table)
Parallel Operation
(*6)
-
Series Operation
(*6)
Possible
Environment
Operating Temperature
(*7)
℃
Ta= -40 to +85
Storage Temperature
℃
-40 to +100
Operating Humidity
%
RH
5 - 95 (No dewdrop)
Storage Humidity
%
RH
5 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz (sweep for 1min.)
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 hour each
Shock
196.1m/s²
Cooling
(*7)
Convection cooled / Forced air cooled
Isolation
Withstand Voltage
Input-Output : 1.5kVDC for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Input-Output...500VDC
Standards Safety Standards
Approved by UL60950-1, CSA 22.2 No.60950-1, EN60950-1
Mechanical
Weight (typ)
g
50
Size (W x H x D)
mm
36.8 x 8.5 x 57.9 (Refer to outline drawing)
■ Basic Connection
■ Option Table
Option
OVP, OCP
Remote ON/OFF control
Standard
Shut down
(ON/OFF control reset or
manual reset)
Negative
(Short : ON,
Open : OFF)
/V
Auto restart
/P
Shut down
(ON/OFF control reset or
manual reset)
Positive
(Short : OFF,
Open : ON)
/PV
Auto restart
(*1) Use an external fuse (fast blow type) for each unit.
(*2) Put output capacitors.
C1: 1µF ceramic capacitor.
C2: 10µF tantalum capacitor or electrolytic capacitor.
(*3) Refer to instruction manual for further details.
Measurement point for Vin
Measurement point for
Vo, Load/Line regulation
Measurement point for
output ripple & noise
(JEITA RC-9141 probe)
Bandwidth of scope:100MHz
LOAD
FUSE 5A
(*1)
Vin
36-76VDC
+Vin
CNT
-Vin
+S
+V
TRM
-S
-V
L=50mm
Cl
1uF
C2
10uF
+
-
(*2)