BEFORE USING THE POWER SUPPLY UNIT

 

 

Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit, or a fire hazard. 

 

 WARNING

 

z

 

  Do not touch heatsinks and case which may be hot. 

z

 

 Confirm connections to input/output terminals and signal terminals are correct as indicated in instruction  manual. 

z

 

 Attach a fast blow type external fuse to each module to ensure safety operation and to acquire each safety standard approval. 

z

 

  This power supply is designed for professional installation within an end user equipment. 

z

 

 The output from this power supply must be considered as an energy hazard (> 240VA power and 2V voltage) and must not be accessible to a user. End equipment manufacturers 
must provide protection against inadvertent contact with the output terminals on this product by a service engineer or by the service engineer dropping a tool into them.  

z

 

 Use isolated voltage by reinforced insulation at primary power supply or double insulation as input power source. 

 
 

NOTE : CE MARKING

 

 

CE marking, when applied to a product covered by this handbook indicates compliance with the low voltage directive (73/23/EEC) as modified by the CE Marking Directive 

      (93/68/EEC) in that it is complies with EN60950. 
 

 

1.   TERMINAL EXPLANATION

 

 

 
 

CNT

+Vin

CASE

-Vin

NAME PLATE

+V

+S

TRM

-S

-V

-Vin

: Negative Input Terminal

CASE : Baseplate Terminal

: ON/OFF Control Terminal

CNT
+Vin

: Positive Input Terminal

-V

: Negative Output Terminal
: Negative Remote Sensing

-S

: Output Voltage Adjustment Terminal

TRM

: Positive Remote Sensing

+S

: Positive Output Terminal

+V

Reviews: