TDK-Lambda LS100 Series Instruction Manual Download Page 5

 

 

   

 

 

 

 

 

 

     

TDK-Lambda 

LS 

25-150 

Series 

INSTRUCTION MANUAL

 

4. Isolation / Withstand Voltage 

4-1. Isolation Test 

Isolation resistance between output and FG (chassis) shall be more than 100M

Ω

 at 500VDC. For safety, voltage setting 

of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test. 
 

(a)

 

Output ~ FG (chassis) : 500VDC, 100M

Ω

 or more 

 

 

AC(L)

 

AC(N)

 

FG

+ V

+V

- V

- V

Isolation 
Tester 

               

 
 

4-2. Withstand Voltage 

This series is designed to withstand 3.0kVAC between input and output, 1.5kVAC between input and FG (chassis) and 
500VAC between output and FG (chassis) each for 1 minute. When testing withstand voltage, set current limit of with-
stand voltage test equipment at 20mA ( Output-FG (chassis) : 100mA ). The applied voltage must be gradually increased 
from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be 
damaged by high impulse voltage at timer switch on and off. Connect input and output as follows : 
 
(a) Input ~ FG (chassis) : solid line 

 

 

 

 

 

(c) Output ~ FG (chassis) : 500VAC, 1min (100mA)             

1.5kVAC, 1min (20mA) 

 
(b) Input ~ Output : dotted line 
   3kVAC, 1min ( 20mA ) 

 

 

 

 

   

 

   

 

AC(L) 

AC(N)

 

FG

 

+V

+V

-V

-V

Withstand 
Voltage 
Tester

 

             

 

AC(L) 

AC(N) 

FG

+V

+V

-V

-V

Withstand
Voltage 
Tester 

 

 
 

Summary of Contents for LS100 Series

Page 1: ...tem equipment and notify in the system instruction manual z Never operate the unit under over current or short circuit conditions for more than 30 seconds or outside its specified Input Voltage Range...

Page 2: ...Output terminal 25A max terminal 5 V Output terminal 25A max terminal 6 Output voltage adjustable trimmer 7 Output monitoring indicator Green LED ON 2 Terminal connecting method z Input must be off w...

Page 3: ...urrent Please select suitable input switch and fuse rating in case of re input the power at high temperature 3 4 Over Voltage Protection OVP The OVP function will shutdown the output except for LS25 T...

Page 4: ...reverse voltage 3 8 Parallel Operation A Operation to increase the Output Current is not possible B Operation as a Backup Power Supply is possible as follows 1 Set the power supply output voltage high...

Page 5: ...5kVAC between input and FG chassis and 500VAC between output and FG chassis each for 1 minute When testing withstand voltage set current limit of with stand voltage test equipment at 20mA Output FG c...

Page 6: ...rating below Please do not use installation Method E where the PCB will be on the topside and heat will be trapped inside the unit In the following derating curve the maximum output current is denoted...

Page 7: ...ent Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature o C LS35 3 3 5 12 15 24 36 48 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Tempera...

Page 8: ...tput Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B D C 70 70 60 45 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 1...

Page 9: ...tput Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 50 70 45 40 Output Derating Vs Ambient Temperature 0 20 40 60 80 100 1...

Page 10: ...utput Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperature C Load Mounting Mounting A B C D 50 70 30 40 Output Derating Vs Ambient Temperature 0 20 40 60 80 100...

Page 11: ...LS100 3 3 5 12 15 24 36 48 NOTE LS25 LS35 LS50 LS75 LS150 series do not require Input Voltage Derating Output Derating Vs Ambient Temperature 0 20 40 60 80 100 120 25 0 25 50 75 100 Ambient Temperatu...

Page 12: ...s must be as thick and short as possible to make lower impedance z Noise can be reduced by connecting a film capacitor with 0 1uF capacitance across the load terminals z For safety and EMI considerati...

Page 13: ...um capacitance shown below Maximum external capacitance MODEL 3 3V 5V 12V 15V 24V 36V 48V LS25 10 000uF 5 000uF 2 000uF 1 000uF 500uF LS35 LS50 10 000uF 5 000uF 2 000uF 500uF LS75 LS150 10 000uF 5 000...