83-517-000 Rev.
A
19
2.8
PROTECTIVE FUNCTIONS
V
8
10
16
20
30
40
60
80
100
150
300
600
1.Foldback protection
---
Output shut-down when power supply changes from CV to CC mode. User-presetable
2. Over-Voltage protection (OVP)
---
Inverter shut-down, manual reset by AC input recycle, by OUT button or by communication port command
3. Over-Voltage trip point
V
0.5~10
0.5~12
1~19
1~24
2~36
2~44
5~66
5~88
5~110
5~165
5~330
5~660
4. Output Under-Voltage limit (UVL)
---
Preset by front panel or communication port. Prevents from adjusting Vout below limit. Does not affect Analog programming.
5. Over-Temperature protection (OTP)
---
User-selectable, latched or non-latched.
2.9
FRONT PANEL
1. Control functions
---
Vout/Iout manual adjust by separate encoders (Coarse and Fine adjustment)
---
OVP/UVL manual adjust by Voltage Adjust encoder
---
Address selection by Voltage Adjust encoder. No of addresses = 31
---
Go-to-Local control
---
Output On/Off
---
AC On/Off
---
Front panel lock/unlock
---
Foldback control
---
Baud rate selection: 1200, 2400, 4800, 9600, 19200
---
Restart modes (Automatic-Restart, Safe-Start)
2. Display
---
4 digits, Accuracy: +/- 0.05% of rated Output v/- 1 count
---
4 digits, Accuracy: +/- 0.2% of rated Output c/- 1 count
3. Indications
---
VOLTAGE, CURRENT, ALARM, FINE, PREVIEW, FOLDBACK, REMOTE (RS-232, RS-485, LAN, IEEE, USB), OUTPUT ON,
FRONT PANEL LOCK
2.10
ENVIRONMENTAL CONDITIONS
1. Operating temperature
---
0 to +50
o
C, 100% load
2. Storage temperature
---
-20
o
C to +85
o
C
3. Operating humidity
%
20% to 90% RH (no condensation)
4. Storage humidity
%
10% to 95% RH (no condensation)
5.Vibration
---
MIL_STD_810F, Method 514.5, EUT is fixed to the vibrating surface
6. Shock
---
Less than 20G, half-sine, 11ms. Unit is unpacked
7. Altitude
---
Maximum 3000m (9843 ft). Derate Output current by 2%/100m (2%/328ft) above 2000m (6562ft)
Alternatively, maximum ambient temperature derated by 1
o
C/100m (1
o
C/328ft) above 2000m (6562ft)
8.RoHS Compliance
---
Complies with requirements of RoHS directive
2.11
MECHANICAL CONSTRUCTION
1. Cooling
---
Forced air flow from front to rear of unit. No ventilation holes at the top or bottom of the chassis. Variable speed fan
2. Dimensions (WxHxD)
mm
W:422.8, H:43.6, D:441.0 (excluding connectors, encoders, handles, etc.)
3. Weight
kg
Less than 10kg (22 lbs)
4. AC Input connector
(with protective cover)
---
Single-Phase 230VAC models: Power Combicon PC 6-16/3-GF-10, 16 Series wit h strain relief
Three-Phase 208VAC/400VAC models: Power Combicon PC 6-16/4-GF-10, 16 Series with strain relief
5. Output connector
---
8V to 100V models
: busbars (hole Ø 10.5mm);
150V to 600V models
: Wire clamp connector, Phoenix P/N FRONT-4-H-7.62
2.12
EMC
1. Applicable standards:
---
2. ESD
---
IEC1000-4-2: Air-discharge
– 8kV, Contact discharge – 4kV
3. Fast Transients
---
IEC1000-4-4: 2kV
4. Surge Immunity
---
IEC1000-4-5: 1kV line-to-line, 2kV line-to-ground
5. Conducted Immunity
---
IEC1000-4-6: 3V
6. Radiated Immunity
---
IEC1000-4-3: 3V/m
7. Magnetic Field Immunity
---
IEC1000-4-8: 1A/m
8. Voltage Dips
---
EN61000-4-11
9. Conducted Emissions
---
EN55022A, FCC Part 15-A, VCCI-A
10. Radiated Emissions
---
EN55022A, FCC Part 15-A, VCCI-A
2.13
SAFETY
1.Applicable standards
UL 60950-1, CSA 22.2 No.60950-1, IEC 60950-1, EN 60950-1
2.Interface classification
Models with Vout
≤ 4
0V
: Output is SELV; LAN, IEEE, USB, RS-232/RS-485, Isolated Analog, J1 Remote Analog (all pins) and Remote sense pins are
SELV; +5VDC and +15VDC Auxiliary Outputs are SELV
Models with 60V
Vout
≤
400V
: Output is Hazardous; LAN, IEEE, USB, RS-232/RS-485, Isolated Analog and J1 Remote Analog (pins 1-3, 14-16)
and +5VDC Auxiliary Output are SELV; Remote sense (all pins), J1 Remote Analog (pins 8-13, 21-25) and +15VDC Auxiliary Output are Hazardous.
Models with 400V < Vout
≤
600V
: Output is Hazardous, LAN, IEEE, USB, RS-232/RS-485, Isolated Analog, J1 Remote Analog (all pins),
Remote sense (all pins), +5VDC Auxiliary Output and +15VDC Auxiliary Output are Hazardous.
3. Withstand voltage
Models with Vout
≤ 4
0V
: Input-Outputs (SELV): 4242VDC - 1minute, Input-Ground: 2828VDC - 1minute
Models with 40V < Vout
≤
100V
: Input (Haz)-Output (Haz): 2600VDC - 1minute; Input (Haz)-SELV: 4242VDC
– 1 minute; Output (Haz)-SELV:
1900VDC - 1minute; Output (Haz)-Ground: 1200VDC
– 1 minute; Input (Haz)-Ground: 2828VDC – 1 minute.
Models with 100V
≤
Vout
≤
600V
: Input (Haz)-Output (Haz): 4000VDC-1 minute; Input (Haz)-SELV: 4242VDC-1 minute; Output (Haz)-SELV: 3550VDC-
1 minute; Output (Haz)-Ground: 2670VDC - 1 minute; Input (Haz)-Ground: 2828VDC- 1 minute.
4.Insulation resistance
More than 100Mohm at 25
o
C, 70%RH