150V to 600V Models
WARNING
Hazardous voltages exist at the outputs and the load connections. To
protect personnel against accidental contact with hazardous voltages,
ensure that the load and its connections have no accessible live
parts. Ensure that the load wiring insulation rating is greater than or
equal to the maximum output voltage of the power supply.
CAUTION
Output Load Wires No Conductor Pretreatment:
Phoenix Contact clamping parts
are designed so that all kinds of copper conductors can be clamped without
pretreatment.
It is forbidden to solder the conductors. The solder tin yields and fractures under high
pressure. The result is increased contact resistance and an excessive temperature
rise. In addition, corrosion caused by pickling or fluxes has been observed on
soldered conductor ends. Notch fractures at the transition point from the rigid to the
flexible conductor area are also possible.