![TDK-Lambda ELC12 Series Instruction Manual Download Page 3](http://html2.mh-extra.com/html/tdk-lambda/elc12-series/elc12-series_instruction-manual_4999967003.webp)
TDK-Lambda
ELC12 Series
INSTRUCTION MANUAL
LONG-TERM STORAGE METHOD AND LONG-TERM STORAGE PERIOD
·
Please keep the product in carton box.
·
Please do not apply excessive vibration, shock or mechanical stress applied directly to the product.
·
Please keep away from direct sunlight.
·
For long-term storage temperature and humidity, the following conditions shall be used as a guideline :
Temperature range : 5℃
~
30℃
Humidity range : 40%
~
60%RH
Please keep away from the places where temperature and humidity can change drastically.
It can cause condensation on the product or deterioration.
·
For long-term storage period, we recommend to use within 2 years after receiving the product.
There is tendency that the leakage current of an aluminum electrolytic capacitor may increase when stored without using for a long
time.
This phenomenon can be improved by applying voltage to the aluminum electrolytic capacitor to reduce the increased leakage
current through the self-recovery effect of the electrolyte.
For reference, before using products that have been stored for a very long
time, please warm-up first for 30 minutes or more without taking load.
< Criterion of warm up voltage condition >
(1)Implementation period : 1 year or above after the delivery
(2)Electrical continuity condition
Input voltage : Rating
Load : 0A
Ambient temperature : Normal temperature
Time : 30 minutes or more