 CAUTION on USE

 

·

 

Product  individual  notes  are  shown in  the instruction  manual.  If  there  is  any  difference  with  common  notes  individual notes  shall 

have priority. 

·

 

Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or damage to the product 
or fire due to improper use. 

·

 

Input  voltage,  Output  current,  Output  power,  ambient  temperature  and  ambient  humidity  should  be  kept  within  specifications, 

otherwise the product will be damaged, or cause electric shock or fire. 

·

 

If the built-in fuse is blown, do not use the product even after replacing the fuse, as there is risk of abnormality inside. Be sure to 

request repair to our company. 

·

 

For products without built-in protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke, fire during  abnormal 

operation. As for products with built-in protection circuit, depending on usage conditions, built-in protection circuit might not work. 
It is recommended to provide separate proper protection circuit. 

·

 

For externally mounted fuse do not use other fuses aside from our specified and recommended fuse. 

·

 

This product was made for general purpose electronic equipment use and is not designed for applications requiring high safety (such 
as extremely high reliability and safety requirements.  Even though high reliability and safety are not required, this product should 
not  be  used  directly  for  applications  that  have  serious  risk  for  life  and  physical  safety.    Take  sufficient  consideration  in  fail-safe 
design  (such  as  providing  protective  circuit  or  protective  device  inside  the  system,  providing  redundant  circuit  to  ensure  no 
instability when single device failure occurs). 

·

 

When used in environments with strong electromagnetic field, there is possibility of product damage due to malfunction. 

·

 

When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.), there is possibility that they might penetrate 

the product and lead to failure. 

·

 

When used in environments where there is conductive foreign matter or dust, there is possibility of product failure or malfunction. 

·

 

Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal voltage. 

·

 

Connect together the frame ground terminal of the product and the ground terminal of the equipment for safety and noise reduction. 

If these ground is not connected together, there is risk of electric shock. 

·

 

Parts  with  lifetime  specifications  (built-in  electrolytic  capacitor)  are  required  to  be  replaced  periodically.  Set  the  overhaul  period 

depending  on  the  environment  of  usage  and  perform  maintenance.  Also,  note  that  there  are  cases  when  EOL  products  cannot  be 
overhauled. 

·

 

Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or overvoltage more than the 

rated voltage to the output might cause failure, electric shock or fire. 

·

 

This product is designed under condition Material group 

b, Pollution Degree (PD): PD2, Over Voltage category (OVC): OVC

 

and Class of equipment: Class 

. This product is designed to be accessible only to service technicians as part of indoor use device. 

Note

 

·

 

Take note that traces of sheet metal processing be left in our power supplies. 

·

 

When disposing product, follow disposal laws of each municipality. 

·

 

Published  EMI  (CE,  RE)  or  immunity  is  the  result  when  measured  in our  standard  measurement  conditions  and  might  not  satisfy 

specification  when  mounted  and  wired  inside  end-user  equipment.  Use  the  product  after  sufficiently  evaluating  at  actual  end-user 
equipment. 

·

 

When exporting our products, apply for necessary permissions as required by rules and regulations of Foreign Exchange and Foreign 
Trade Control Act. 

·

 

Catalogue, contents of the instruction manual may be changed without a prior notice. Refer to latest catalogue or instruction manual. 

·

 

Reproduction or reprinting the instruction manual or its portion is forbidden without our permission. 

 

Summary of Contents for ELC12 Series

Page 1: ...contact us Do not attempt repair by yourself as it is dangerous for the user Do not operate and store these products in environments where condensation occurs due to moisture and humidity It might le...

Page 2: ...e gas hydrogen sulfide sulfur dioxide etc there is possibility that they might penetrate the product and lead to failure When used in environments where there is conductive foreign matter or dust ther...

Page 3: ...ng term storage period we recommend to use within 2 years after receiving the product There is tendency that the leakage current of an aluminum electrolytic capacitor may increase when stored without...

Page 4: ...C 12 18 R70 Rated Output Current 1 1 R35 0 35A R70 0 70A Rated Output Voltage 2 2 18 3 18V 36 6 36V Output Power Type Series Name 2 Terminal Explanation a L Input terminal Brown Live line Fuse in line...

Page 5: ...tage Output Voltage 0V Vout 0V Input on Input off OVP point Iout V LED 0A OVP act on Output Current LED turn on LED turn off L N Input 90 265VAC FG Output Output current Sensing Inrush Current Limit C...

Page 6: ...not subject the unit to scratch and undue stress such as bending or pulling the input and output wires When connecting wire connect firmly by ensuring no loose connection omission and no wire being p...

Page 7: ...fixed and cannot be adjusted externally 6 4 Output Voltage low condition Output Ripple becomes large at several conditions such as 100V input system Vin 90 to 169VAC when output voltage is set at app...

Page 8: ...between input and earth for one minute When testing withstand voltage set current limit of withstand voltage test equipment at 10mA The applied voltage must be gradually increased from zero to testin...

Page 9: ...or piling up one unit over the other Even when operating ambient temperature is thought to be within the limits of power supply specification if the power supply is enclosed in a sealed device or app...

Page 10: ...ons such as 100V input system Vin 90 to 169VAC when output voltage is set at approximately 40 or less than the rated voltage and 200V input system Vin 170 to 265VAC when output voltage is set approxim...

Page 11: ...there is no influence before using 10 Light modulation control Never adjust light modulation control by the PWM switch etc that is connected to the output side of ELC series This might cause damage to...

Page 12: ...lytic capacitor The life is described in reliability data The life of the aluminum electrolytic capacitor varies depending on the method of mounting the power supply the load current and the ambient t...

Reviews: