4. Sequence Time Chart
7/20
0V
Vout
0V
Input on
Input off
Input on
Input off
OVP point (*1)
Input Voltage
Output Voltage
Remote ON/OFF
Control (*2)
+RS/+RO
-R
Remote off
Remote on
OV
P
act
on
OCP
act
on
OCP
reset
OCP
act
on
Remote off
Remote on
5V
0V
Standby voltage
(*1) OVP detection point is fixed. Refer to specification.
(*2) External switch is required. Refer to section 6-13
“
Remote ON/OFF control
”
.
(*3) Peak loading duration more than specified timing is caused output to shutdown (delay shutdown).
e.g. More than 5 sec at 800W peak loading, More than 1 sec at 1000W peak loading.
Delay shutdown time is depended on peak loading.
(*4) OCP condition more than 1 sec is caused output to shutdown (delay shutdown).
Remote off
Remote on
Delay shutdown (*3)
Peak loading (*3)
Delay shutdown (*4)