23. Safety Approvals
UL/CSA 60950-1, IEC/EN60950-1
Intended for installation in a non-operator access environment
Intended for installation in an external electrical/mechanical/fire enclosure
24. EMC & Immunity
Conducted Emissions - EN55022/EN55032 Class B
Radiated Emissions - EN55022/EN55032 Class A
Immunity - EN61000-4-2, -3, -4, -5, -6, -8, -11, -12, -14
25. Fault Finding
If the unit shuts down, cycle the AC power to the supply. The over voltage or over temperature protection
circuit may have been activated thus shutting down the output. In the event of an over temperature condition,
ensure the unit has cooled down before re-applying the AC input.
When recovering from a fault, the output recovery may be delayed for up to 20 seconds to allow for proper
start-up. If the unit still fails to power up, return to TDK-Lambda Americas for evaluation and repair.
26. Connector Locations
J2, J3 (Output Signals)
J6, J7 (Address Jumpers)
See I
2
C section for more details
J4 (Local ON/OFF Jumper)
Jumper overrides ON/OFF signal
from output connector. Unit is always
enabled.