CPFE1000FI SERIES
POWER SUPPLY
OPERATION MANUAL
19
19 August 2020
For Model CPFE1000FI-28/C (also represents CPFE1000FI-28/CH):
Output Rating (DC)
Orientation
Voltage (V)
Current (A) @
90-135 V ac
Power Max
(W)
Current (A) @
170-265 V ac
Power Max
(W)
A
28 (22.4–
33.6)
36 @ 30°C
34 @ 40°C
32 @ 50°C
30 @ 60°C
28 @ 70°C
1008 @ 30°C
952 @ 40°C
896 @ 50°C
840 @ 60°C
784 @ 70°C
36 @ 30°C,
40°C, 50°C,
60°C & 70°C
1008 @ 30°C,
40°C, 50°C,
60°C & 70°C
B
36 @ 40°C
34 @ 50°C
32 @ 60°C
30 @ 70°C
1008 @ 40°C
952 @ 50°C
896 @ 60°C
840 @ 70°C
36 @ 40°C,
50°C, 60°C &
70°C
1008 @ 40°C,
50°C, 60°C &
70°C
C
36 @ 45°C
35 @ 50°C
33 @ 60°C
31 @ 70°C
1008 @ 45°C
980 @ 50°C
924 @ 60°C
868 @ 70°C
36 @ 45°C,
50°C, 60°C &
70°C
1008 @ 45°C,
50°C, 60°C &
70°C
D
36 @ 50°C
34 @ 60°C
32 @ 70°C
1008 @ 50°C
952 @ 60°C
896 @ 70°C
36 @ 50°C,
60°C & 70°C
1008 @ 50°C,
60°C & 70°C
E
36 @ 45°C
35 @ 50°C
33 @ 60°C
30 @ 70°C
1008 @ 50°C
980 @ 60°C
924 @ 60°C
840 @ 70°C
36 @ 45°C,
50°C, 60°C &
70°C
1008 @ 45°C,
50°C, 60°C &
70°C
F
33 @ 25°C
31 @ 40°C
30 @ 50°C
28 @ 60°C
26 @ 70°C
924 @ 25°C
868 @ 40°C
840 @ 50°C
784 @ 60°C
728 @ 70°C
36 @ 25°C,
40°C, 50°C,
60°C & 70°C
1008 @ 25°C,
40°C, 50°C,
60°C & 70°C
Test orientations are as follows:
A – Horizontal – components pointed toward the top
B – Sideways – input connector on the left and output connector on the right
C – Sideways – input connector on the right and output connector on the left
D – Vertical – input connector pointed towards the bottom and output connector pointed towards the top
E – Vertical – input connector pointed towards the top and output connector pointed towards the bottom
F – Horizontal – components pointed toward the bottom
Note: Baseplate temperature not to exceed
85°C
on all orientation.