All specifications are subject to change without notice.

  Input Voltage Range

Input voltage range is single phase 85 - 265VAC (47 - 63Hz) or 
120 - 370VDC. Input voltage which is out of specification may 
cause unit damage. For cases where conformance to various 
safety specs(IEC,UL,CSA,EN) are required, input voltage range 
will be 100 - 240VAC(50/60Hz).

  Output Voltage Range

V.ADJ trimmer(VR51) that is nearly output connector can adjust 
the output voltage within the range. Output voltage range is 
within CME150 : ±10%, CME240P : -10

 +20% of nominal out-

put voltage. To turn the trimmer clockwise, the output voltage 
will be increased. Note over voltage protection ( OVP ) function 
may trigger if the output voltage is increased ex-cessively.

  Inrush Current

This model has used Power Thermistor to pro-tect the circuit 
from Inrush Current. Please carefully select input switch and 
fuse in cases of the high temperature and re-input the power.

  Over Voltage Protection (OVP)

The OVP function ( Inverter shut down method, manual reset 
type  )  is  provided.  OVP  function  operates  within  CME150: 
115-135%,  CME240P:125-145%  of  nominal  output  voltage. 
When OVP triggers, the output will be shut down. The input 
shall be removed for a few minutes, and then re-input for re-
covery of the output. OVP setting shall be fixed and not to be 
adjusted externally.

  Over Current Protection (OCP)

Constant current limiting, automatic recovery. OCP function 
operates  when  the  output  current  exceeds  CME150:125%, 
CME240P:205% of maximum output current of specification. 
The output will be automatically recovered when the overload 
condition is re-moved. Do not operate overload or dead short 
conditions for more than 30 seconds, which could result in 
damage or insulation failure.

  Output Ripple & Noise

The standard specification for maximum ripple value is mea-
sured according to measurement cir-cuit specified by JEITA-
RC9131. When load lines are longer, ripple becomes larger. In 
this case, electrolytic capacitor, film capacitor, etc., might be 
necessary to use across the load terminal. The output ripple 
cannot be measured accurately if the probe ground lead of os-
cilloscope is too long.

  Series Operation

For series operation, either method (A) or (B) is possible.

Method (A)                                 Method (B)

 

 

  Parallel Operation 

A

  To increase the output current is not possible.

 
 

B

  To use as Back-up Power Supply

1. 

Set power supply output voltage higher by the forward 

voltage drop(V

F

) of diode.

2. 

Adjust the output voltage of each power supply to be the 

same.

3. 

Use within the specifications for output voltage and out-

put power.

 

  Peak Output Current 

CME150

For CME150-24, relation with average output current and peak 
output current must satisfy formulas below. Also operating 
time at peak output is less than 10sec. 
When using pulse load, audible noise can be heard from power 
supply unit.

Ip  : Peak output current (A)
Iav : Average output current 
 

  (Maximum output current of Specification (A))

Im : Average output current (A)

τ

  : Pulse width of peak output current (sec)

 

  (Operating time at peak output)

T  : Period (sec)

3. Explanation of Functions and Precautions

Input

L

R

C1

Oscillo Scope
Bandwidth : 100MHz

N FG

P.S. C2

150mm

Load

1.5m 50Ω Cable

C3

+

+

-

R  : 50Ω

C1: 4700pF film capacitor

C2: 100μF electrolytic capacitor

C3: 0.1μF film capacitor

Output

Terminal

Output

Terminal

Load

Load

Output

Terminal

Output

Terminal

Load

Output

Terminal

Output

Terminal

Load

Output

Terminal

Output

Terminal

Load

Ip

0A

Im

T

Iav≥Im= Ip×

T

Ip

0A

aA

Im

T

Iav≥Im= (Ip-a)×

T

+a

Summary of Contents for CME Series

Page 1: ...E240P 24 Output voltage 24V 24V Max output current 6 3A 10A Max output power 151 2W 240W Peak output current 7 5A 20A Peak output Power 180W 480W UL60601 1 CSA 22 2 No 601 1 M90 cUL certified EN60601...

Page 2: ...Standards Safety Standards 12 Approved by UL60601 1 EN60601 1 Built to meet UL60950 1 CSA60950 1 EN60950 1 and DENAN PFHC Built to meet EN61000 3 2 EMI 13 Built to meet EN55011 EN55022 B FCC ClassB VC...

Page 3: ...1 1 J S T 9 11 HAND CRIMPING TOOL YC 160R MANUFACTURER J S T 37 1 80 1 70 0 5 Ground the FG to the safety ground of the equipment or device There must be at least 4 mm gap between the end of the print...

Page 4: ...romagnetic field erosive gas etc or any environment where conductive foreign substance may enter Do not operate and store this unit at the condition of condensation In such case waterproof treatment i...

Page 5: ...EN60601 1 2 EMC but EMC test data is available from TDK LAMBDA Corporation Special Instructions for IEC EN UL 60601 1 1 Terminal Explanation CME150 CME240P 1 L AC input terminal pin 1 of CN1 Live lin...

Page 6: ...erload or dead short conditions for more than 30 seconds which could result in damage or insulation failure Output Ripple Noise The standard specification for maximum ripple value is mea sured accordi...

Page 7: ...ge load after derating by vari ous Mounting and Ta Examples of peak load derating calculated by above formula Actual Io Average Load Io A Ip A max D max Im A Io A 100 10 20 35 0 3 92 9 55 90 9 20 30 4...

Page 8: ...lso use all 4 mounting holes for the unit installation The vibration spec is the value taken when the unit is raised by 8mm spacers And allowable area by metal pieces is 9mm from each PCB corners Refe...

Page 9: ...igh braking capac ity fuse when selecting the external fuses that are to be used on input line Surge current flows when line turns on There fore use slow blow fuse or time lug fuse Do not use fast blo...

Page 10: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information TDK Lambda CME240P 24...

Reviews: