INSTRUCTION MANUAL
CCG15
・
30
Series
TDK-Lambda
<Page>
13/23
6-4. Maximum Line Regulation
Maximum value of output voltage change when input voltage is gradually varied (steady state) within
specified input voltage range.
6-5. Maximum Load Regulation
Maximum value of output voltage change when output current is gradually varied (steady state) within
specified output current range.
When using at dynamic load mode, output voltage fluctuation might increase.
Also, when CCG-D is used with unbalanced load, the output voltage with the higher load factor
decreases and the output voltage with the lower load factor increases.
A thorough pre-evaluation must be performed before using this power supply.
6-6. Over Current Protection (OCP)
This power supply has built-in OCP function.
When short circuit or output current is in overload condition, it becomes intermittent operation.
Output will recover when short circuit or overload conditions are released.
Take note that power supply might be damaged at continuous overload conditions depending on
thermal conditions.