background image

 

MA00101E00  V_1.3

 

5

 

 

 

N.PIN

 

Descriptions

 

1

 

PROG. -> On=Converter in program mode Off= terminal mode 

 

2

 

Term+ ON = Term+ and PullUp on the rx+ line (only in the first and the last 

receivers)

 

3

 

ON = RS485 2wire  OFF= RS422 4wire

 

4

 

Term- ON = Term- and PullDw on the rx- line (only in the first and the last 

receivers)

 

 

Open/Close both dip2 and dip4 together for bus termination.

 

Be carefull do not leave the floating potential GNDExt but fix it on the ground in just only one point

.

 

 

 

 

 

6  SOLDER SWITCH 

Solder switch monitor 

options

 

Default = RS232

 

Monitor options

 

K1

 

1-2 Closed / 2-3Open

 

1-2 Open / 2-3 Closed 

 

K3

 

 

 Closed

 

 

Solder switch

 

Descriptions

 

K2

 

Close only for compatibility with old OPD

 

K7

 

Power supplies from USB when use RS232 to RS422 

without USB initialization/use

 

 

7  THE CONCEPT OF THE SISTEM 

 

7.1

 

WHEN A TX DATA AS TRANSMITTED BOTH THE OTHERS PORTS RECEIVE 

THAT DATA 

 

These three examples show the relationship between the sender and who receivers.

 

If we don't use the USB connector the converter need an external 5V on USB connector or from the pin1-6 of 

CN2.It is possible to use a normal USB power supplies on the USB cable but the internal K7 solder switch 

must be close

 

 

 

 

 

 

 