3. Description

The measurement types analogue signal and AC/DC shunt are supported. Minimum
and   maximum   values   are   recorded   and   can   be   displayed   optionally   using   an
external switch. Measured values are recorded over a time span of 36 seconds up to
14   days.   The   time   base   as   well   as   the   display   of   the   measure   history   can   be
switched by an external switch. The measured values remain stored as long as the
device is supplied with voltage.
The following parameters can be adjusted using the configuration software “Digalox

®

Manager”:   scale   endpoint,   scale   caption,   display   style   (pointer,   tachometer,   bar
graph, and more), splash image, thresholds for alarm output, hysteresis, and more.
Recorded measurement values can be read and a continuous transmission of the
actual measuring value can be enabled. Using the software, values can be viewed
and exported as CSV.

Front

1

Unit or free text

2

Threshold values

3

Upper scale caption

4

Graphical measurement display

5

Digital measurement value

6

Lower scale caption

Back

1

2 optocoupler switch outputs

2

DIP switch for setting upper scale 
caption and display value (mode)

3

Supply voltage input

4

Jumper pins J1 – J6 for 
activating/switching of graphical 
historic data display, min/max display,
auto-scaling and display value (mode)

5

USB Micro-B interface

6

Measurement inputs

----- 

2

 -----

Summary of Contents for Digalox DPM72-PP

Page 1: ...device hazardous voltages must not be connected to the device The device must not be used as the only protective device or protective shutdown Read instruction manual carefully before operating the d...

Page 2: ...ion display style pointer tachometer bar graph and more splash image thresholds for alarm output hysteresis and more Recorded measurement values can be read and a continuous transmission of the actual...

Page 3: ...Digalox Load Shunt U 50 V max 200 mV Ilow Ihigh Uhigh Ulow L N Legend Current source e g active sensor or sensor with voltage supply WARNING The device may only be operated in one of the connection o...

Page 4: ...display value or the one that is selected by the jumpers J4 J6 or the DIP switches 11 12 respectively see table display value Scaling via DIP switches If the scaling to represent the correct display v...

Page 5: ...lues repeat steps 3 8 until all required display values are configured The time base does not need to be set again as it is used for all display values 10 In operation the display values can be change...

Page 6: ...2 3 4 5 6 7 8 9 1 0 1 1 1 2 Table display value factory preset can be changed by software Display value Display Scale Manual mode Save mode 60 mV DC scaled shunt Ampere DC Upper scale caption ON 1 2 3...

Page 7: ...sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting permanently DIP...

Page 8: ...mpere 20 mA AC DC max 100 mA 10 500 Hz Accuracy ampere 0 5 true RMS Internal resistance ampere 6 2 Measuring value update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 i...