 DPM72-PP Instruction manual 

(Rev-2021-07)

Visit 

www.digalox.com

 to download the software “Digalox

®

 Manager”.

Package contents: 

Panel meter Digalox

®

 DPM72-PP, mounting bracket,

5 jumpers, 2 instruction manuals (EN + DE)

1. Intended Use

Indoor use non condensing, non corrosive.

Panel mounting.

Failure to comply with these instructions will void all guarantee and warranty.

In operation, supply the device preferably via screw terminals with 12 to 24 V
AC/DC instead of via USB.

2. Safety instructions

Note:   The   measurement   inputs   of   the   device   can   carry   life-threatening
voltages!

When working on the device hazardous voltages must not be connected to
the device!

The device must not be used as the only protective device or protective
shutdown. 

Read instruction manual carefully before operating the device!

The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).

When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 10 V switches must be isolated for at
least 20 V.

Do not open the housing!

Do not use the device in the presence of explosive or flammable substances!

All cables carrying hazardous voltages must be secured with external separators.

----- 

1

 -----

Summary of Contents for Digalox DPM72-PP

Page 1: ...device hazardous voltages must not be connected to the device The device must not be used as the only protective device or protective shutdown Read instruction manual carefully before operating the d...

Page 2: ...ion display style pointer tachometer bar graph and more splash image thresholds for alarm output hysteresis and more Recorded measurement values can be read and a continuous transmission of the actual...

Page 3: ...Digalox Load Shunt U 50 V max 200 mV Ilow Ihigh Uhigh Ulow L N Legend Current source e g active sensor or sensor with voltage supply WARNING The device may only be operated in one of the connection o...

Page 4: ...display value or the one that is selected by the jumpers J4 J6 or the DIP switches 11 12 respectively see table display value Scaling via DIP switches If the scaling to represent the correct display v...

Page 5: ...lues repeat steps 3 8 until all required display values are configured The time base does not need to be set again as it is used for all display values 10 In operation the display values can be change...

Page 6: ...2 3 4 5 6 7 8 9 1 0 1 1 1 2 Table display value factory preset can be changed by software Display value Display Scale Manual mode Save mode 60 mV DC scaled shunt Ampere DC Upper scale caption ON 1 2 3...

Page 7: ...sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting permanently DIP...

Page 8: ...mpere 20 mA AC DC max 100 mA 10 500 Hz Accuracy ampere 0 5 true RMS Internal resistance ampere 6 2 Measuring value update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 i...

Reviews: