Electrostatic Oil Mist Collector CE Series

 

13 
 

5.Installation and operation instructions 

5.1 

Installation instructions 

    

   5.1.1.

  

Check the main voltage and frequency by comparing the 

specification on the utility meter with the specification on the 

machine rating plate.

 

The power supply needs to be grounded. Be sure to 

turn off the primary power side before installing the machine. Primary 

side 3 phase circuit breaker rated current should be 15A large then 

the collector rated current.  

10 

 

11 

The voltage fluctuations must be in the range of -5 % to 10 %. In 

12 

case of major fluctuations, faults and premature wear can be expected. 

13 

In this case, the warranty will no longer be valid.  

14 

 

15 

   5.1.2. Depending on customer field application, CE series of 

16 

collectors have three installation ways: 

17 

(1)

 

Install on the machine directly. 

18 

(2) Install on support column (Support column height customizable). 

19 

(3) Whole factory machine tools oil mist solution. Solution is 

20 

proceeded with CE series collectors and air duct.   

21 

 

22 

   5.1.3.

 

Oil mist intake place suggestions: 

23 

   5.1.3.1 Usually set oil mist intake place on machine tool top cover 

24 

or side cover. 

25 

   5.1.3.2 Oil mist intake place should prevent nearby or opposite 

26 

machine tool coolant nozzle. If this situation could not be prevented, 

27 

user should install oil mist intake cover (plastic/steel) to reduce 

28 

oil drop intake volume.  

29 

5.1.4. Connection between air duct and CE series collectors should not 

30 

leak, and air duct layout should prevent oil accumulation inside air 

31 

duct. Also, 

could install “Front oil blocker”

 or PVC pipe to 

32 

prevent above problem.  

33 

 

34 

Summary of Contents for CE Series

Page 1: ...TCSM MC CO LTD TEL 886 4 7331657 FAX 886 4 7330116 EMAIL assa tcsm gmail com chenshin h gmail com Office Add No 66 Aly 208 Bianxing Ln Xuetian Rd Wuri Dist Taichung City 414011 Taiwan R O C Factory Ad...

Page 2: ...Circuit diagram 9 0 5 Installation and operation instructions 13 1 5 1 Installation instructions 13 2 5 2 Operation instructions 14 3 5 2 1Interface 14 4 5 2 2 Before starting up 15 5 5 2 3 Starting u...

Page 3: ...ist 1 2 The blocking zone 2 Block large oil mist by front filter to improve the efficiency of the 3 electric field filter 4 3 Electric field filter 5 Electrode plate got positive plate and negative pl...

Page 4: ...Depending on Table 1 Collector weight use appropriate vehicle to move Collector like Stacker Person who using the vehicle must have relevant knowledge and qualification to carry it 1 3 Disposal instru...

Page 5: ...0 Air flow volume m3 h 900 1000 1800 2200 Power kW 0 45 0 45 0 875 1 275 Noise dB A 70 75 79 79 Motor frequency Hz 50 50 Motor rotating speed r min 2500 2860 1430 2860 Net weight kg 75 115 Physical di...

Page 6: ...Electrostatic Oil Mist Collector CE Series 5 3 CE series spare parts 1 3 1 CE 900 2 3...

Page 7: ...Electrostatic Oil Mist Collector CE Series 6 3 2 CE 1000 1 2...

Page 8: ...Electrostatic Oil Mist Collector CE Series 7 3 3 CE 1800 1 2...

Page 9: ...Electrostatic Oil Mist Collector CE Series 8 3 4 CE 2200 1 2...

Page 10: ...Electrostatic Oil Mist Collector CE Series 9 4 Circuit Diagram 1 4 1 CE 900 2 3...

Page 11: ...Electrostatic Oil Mist Collector CE Series 10 4 2 CE 1000 1 2...

Page 12: ...Electrostatic Oil Mist Collector CE Series 11 4 3 CE 1800 1 2...

Page 13: ...Electrostatic Oil Mist Collector CE Series 12 4 4 CE 2200 1 2...

Page 14: ...pending on customer field application CE series of 6 collectors have three installation ways 7 1 Install on the machine directly 8 2 Install on support column Support column height customizable 9 3 Wh...

Page 15: ...rtical to oil pail this 9 oil recycle tube must turn a circle and fill 0 oil in this circle 1 The end of oil recycle tube need higher than 2 oil level in pail The purpose of this 3 arrangement is to p...

Page 16: ...the rotation of the motor turn on 4 the main power switch At this time the 5 operating error light may flash Please confirm 6 whether it is still flashing after 5 minutes If 7 still flashing turn off...

Page 17: ...hod please refer to 6 3 1 Manual cleaning 6 CE series Oil Mist Collector monthly maintenance schedule M Y Item Check Parts Situation Maintenance Checked 1 Front filter If filter can t clean up by pres...

Page 18: ...ror code can not solve plaese check Shihlin SE3 SC3 inverter user manual follow invertermanual instruction or contect supplier 6 2 3 Operating Error light flashing 1 Electrode Plate dirty 2 Electrode...

Page 19: ...rostatic plate including each plate with the detergent And use a brush to remove stains then rinse repeatedly with detergent After cleaning spray the detergent full and let it stand for 10 minutes unt...

Page 20: ...part according to the monthly maintenance plan If there is no problem check plan out and put the plate back into Collector 6 3 2 Ultrasonic cleaning 1 Item Icon Instruction 1 Please choose a neutral...

Page 21: ...ction If user cannot confirm whether water has been totally removed please let Electrode plate sit for a period of time to remove remaining water 4 After cleaning check the condition of each part acco...

Page 22: ...h the 8 information below 9 0 1 2 3 4 CHEN SHIN TCSM MC CO LTD TEL 886 4 7331657 FAX 886 4 7330116 EMAIL assa tcsm gmail com chenshin h gmail com Office Add No 66 Aly 208 Bianxing Ln Xuetian Rd Wuri D...

Page 23: ...Electrostatic Oil Mist Collector CE Series 22 8 EC declaration of conformity 1 2...

Reviews: