background image

Valid for Australia and New Zealand

Q.Pro-G3 · Q.Pro BLK-G3 · Q.PeaK-G3 · Q.PLUS-G3

InstallatIon and 

operatIon Manual

Summary of Contents for Q.Peak-G3

Page 1: ...Valid for Australia and New Zealand Q Pro G3 Q PRO BLK G3 Q Peak G3 Q PLUS G3 Installation and Operation Manual ...

Page 2: ...procedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations The solar module operator is responsible for compliance with all applicable statutory requirements and regulations Ä Ä The following regulations and standards must be upheld at all times during the i...

Page 3: ... for the functionality and safety of the modules Ä Ä Please observe the instructions for any other sys tem components that may be part of the complete solar power system It may be necessary to carry out a structural analysis for the entire project Ä Ä If your questions are not satisfactorily answered in the manual please contact your system supplier Additional information can be found on our websi...

Page 4: ...ened to the ground the roof or the façade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Guarantees long term stability Has electrochemical series that prevent corrosion among different metals Allows for stress free expansion and contraction due to temperature fluctuations Ä Ä Ensure that no mechanical stresses e g caused by v...

Page 5: ...ounting options Specifications Module type Mounting option Clamping range1 Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PRO G3 Q PRO BLK G3 Q PEAK G3 Q PLUS G3 CL1 Push 245 345 346 445 3500 2400 5400 Pull 245 345 346 445 5650 4000 CL3 Push 245 445 5700 Pull 245 345 346 445 4000 4000 CL4 Push 0 300 2000 Pull 0 300 2000 FB1 Push 3500 Pull 3100 FB2 Push 4000 Pull 3100 IP1 Push 3700 Pull 37...

Page 6: ...ground leaks or defective insulation Ä Ä Ensure that the maximum reverse current load capacity indicated in the data sheet is observed In order to limit reverse currents that may occur we recommend using the following safety options 1 Layout with a limited number of parallel connected strings Refer to AS NZS 5033 2012 including all relevant amendments for parallel string overcurrent protection req...

Page 7: ... packaging until installation Ä Ä Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Ä Ä Do not install damaged modules Ä Ä Inform your dealer of any damages immediately 3 1 Safety and transport 3 Installation Note Module damage may occur Ä Ä Never lift or move the module with the connection cables or junction box Ä ...

Page 8: ... in windy or wet weather Danger Risk of fatal injury due to electric shock Ä Ä Only use dry insulated tools Ä Ä Do not carry out the installation alone Only install undamaged modules and components Ä Ä Do not drill any other holes 3 2 Preparation of installation 3 Installation Ä Ä Maintain an interval of at least 10 mm between two modules 10mm 1 0 m m Option 2 Ä Ä Install the module at the 4 mount...

Page 9: ...e wiring with extreme caution Ä Ä Ensure that the modules are disconnected at the inverter prior to separation Ä Ä Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge Danger Risk of fatal injury due to electric shock Ä Ä Never open the junction box Ä Ä Do not remove bypass diodes Danger Risk of fatal injury due to electric...

Page 10: ...c shock Ä Ä Ensure that all electrical components are in a proper dry and safe condition A module with 1 160 mm long cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return cable Standard wiring with a return cable Inverter Inverter 1 2 4 3 Connection of modules 4 ELECTRICAL CONNECTION Ä Ä Ensure that all necessary safety and functional tests have been carried out accor...

Page 11: ...e Maintenance Ä Ä The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all electrical components are clean and undamaged Cleaning WARNING Risk of injury due to hot and live modules Ä Ä Only clean modules that have cooled down Ä Ä Do not carry or wear any electrically conductive parts WA...

Page 12: ...4 20 Berry Street North Sydney NSW 2060 Australia TEL 61 0 29016 3033 FAX 61 0 269016 3032 EMAIL q cells australia q cells com WEB www q cells com au Subject to change without notice Hanwha Q CELLS GmbH Installation manual G3 modules_2015 02_Rev06_AU ...

Reviews: