background image

PI_GB_PES_PDS_Art0015689_1v0.doc 12 

10/2005 

Programming a bell button  

 

Connect the in-house station to the TCS:BUS. 
Use one of these two methods. 
 

Method 1

In-house station not accessible

 

1

 LED 

illuminates 

 
 
 
 
 
 

 

Press briefly 

LED flashes  

 
 

programming 
mode 
of system 
switched on 

 

 

 

 

 

Floor-switch button within 3 sec: 

 

press 1 sec, until bell rings - release - press 1 sec until bell rings - release. 

 
 
 


 
 
 
 
 
 

 

Press briefly 

ring tone sounds at front-door and in-house station

1)

 
 
 

bell button 
programmed 

4  
 
 
 
 
 

 

Press briefly 

LED illuminates 

 
 

programming 
mode 
of system 
switched off 

 

 

 

 

Programming the other bell buttons: 

• 

Step 

1

 

• 

repeat steps 

2

 and 

3

 each time 

• 

complete the programming of all buttons with step 

4

 

 
 
 
 
 
 

TCS TürControlSysteme AG  

  Geschwister-Scholl-Str. 7 

 

 

  39307 Genthin 

Subject to change without notice. 

Phone: +49 39 33 / 87 99 10  

  Fax: +49 39 33 / 87 99 11  

  www.tcs-germany.com 

Art.Nr.    0015689  Version 1.0  mi 

 

Summary of Contents for PDS Series

Page 1: ...or surface mounting Profi Economic PES Profi Design PDS TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Subject to change without notice Phone 49 39 33 87 99 10 Fax 49 39 33 87 99 11 www tcs germany com Art Nr 0015689 Version 1 0 mi ...

Page 2: ...of a bell button 11 Testing 11 Deleting the programming 11 Programming a bell button 12 Method 1 In house station not accessible 12 Programming the other bell buttons 12 Method 2 In house station accessible 13 Programming the other bell buttons 13 Programming an already programmed bell button 14 Basic principle 14 Method 1 In house station not accessible 14 Programming the other already programmed...

Page 3: ... with VDE 0800 must be observed separate cabling for high and low voltage lines minimum distance of 10 cm for joint cabling arrangements use of separators between high and low voltage lines in joint cable ducts use of standard telecommunication cables e g J Y St Y with 0 8 mm cross section existing cables rationalisation with different cross sections may be used whilst taking account of the loop r...

Page 4: ...ect the screens to each other and connect on one side to earth b wire on the power supply unit Choice of line or star wiring rt red gn green bl blue br brown ws white sw black ge yellow Table loop resistances Cable cross section Cable length in m 0 6 mm 0 8 mm Loop resistance in Ω 10 1 22 0 69 20 2 45 1 38 30 3 67 2 07 40 4 90 2 76 50 6 12 3 44 60 7 35 4 13 70 8 57 4 82 80 9 80 5 51 90 11 02 6 20 ...

Page 5: ...les 3 4 condensate drainage Shown is the PES12 without name plate glass Technical data Supply voltage 24 V 8 via power supply and control unit Case aluminium anodised Name plate glass plexiglass Operating temperature range 20 C to 50 C Input current I a 0 4 mA I P 16 mA standby Maximum input current I Pmax 65 mA TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Subject to change with...

Page 6: ...rammed data serial numbers and parameters are stored in the EEPROM If the front door station re quires replacement the EEPROM board can be removed from the programmed front door station and inserted into the new front door station of identical design Additional functions Name plate illumination via LED P wire connection required connection for Service Device for PES PDS for connection of a bell bu...

Page 7: ...e back 4 Closing the housing Slide the name plate glass upwards under the front panel Turn the lower panel to the right until the re cess fits over the screw Tighten the screws When sliding the name plate glass upwards take care not to damage the rubber seals in the guide grooves When fitting additional devices make sure that you can slide the name plate glass of the device downwards out of the pr...

Page 8: ...m type in accordance with the connection dia gram 2 wire special mode In this mode only one front door station can be con nected A P wire has to be made by bridging termi nals a and P Note The front station does not work if the bridge is connected to b instead of a Wiring example To connect a door release relay use the R terminal A door release contact can be connected to the S terminal This allow...

Page 9: ... volume will cause a feedback effect whistling Nameplate labelling The templates are available on our website www tcs germany com English Downloads System and technology basics Product installa tion and use labelling of the nameplate 1 Enter the desired name into the template 2 Print the name plate on the special film and cut it to size 3 Loosen the pockets at the outer edge of the name plate glas...

Page 10: ...ns in the flats The voltage supply is provided by connecting the Service Device to the TCS BUS For more on the TCS Service Sevice see www tcs germany de If you do not have the Service Device you can also program manually Programming steps legend briefly press key LED flashes slowly press key until LED flashes rapidly release key ring tone NoProg tone continue wait until Prog2 tone Delation tone Pr...

Page 11: ...t be deleted Deleting the programming 1 Press briefly LED flashes programming mode of system switched on 2 Press deletion tone release until sounds1 bell button deleted 3 Press briefly LED flashes no more programming mode of system switched off 1 If Progsperr ton sounds the programming block is active It can be removed by the service device TCSK 01 only TCS TürControlSysteme AG Geschwister Scholl ...

Page 12: ...gs release press 1 sec until bell rings release 3 Press briefly ring tone sounds at front door and in house station1 bell button programmed 4 Press briefly LED illuminates programming mode of system switched off Programming the other bell buttons Step 1 repeat steps 2 and 3 each time complete the programming of all buttons with step 4 TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin...

Page 13: ...door and in house station1 bell button programmed 3 Press briefly LED illuminates programming mode of system switched off Programming the other bell buttons Step 1 repeat step 2 each time for additional bell buttons where necessary complete the programming of all buttons with step 3 TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Subject to change without notice Phone 49 39 33 87 9...

Page 14: ...n 2 Floor switch button within 3 sec press 1 sec until bell rings release press 1 sec until bell rings release 3 Press and and ring tone sounds release until Noprog tone at front door and Prog2 tone sounds1 sounds in house station bell button programmed 4 Press briefly LED illuminates programming mode of system switched off Programming the other already programmed bell buttons Step 1 repeat steps ...

Page 15: ...amming mode of system switched off Programming the other already programmed bell buttons Step 1 repeat step 2 each time for additional bell buttons where necessary complete the programming of all buttons with step 3 Note Repeated programming of an already programmed bell button always only changes the second serial number If you want to change the first programmed serial number you have to delete ...

Page 16: ...door station Take care that all four poles of the plug are inserted into the jack of the small PCB and that the component side is visible After replacement all programming is available again Cleaning Avoid water entering the device Do not use any aggressive or abrasive cleaning agents Clean the device using a dry or slightly moist cloth More persistent dirt can be removed using a mild household cl...

Reviews: