Connect the lines
Minimize the length of the lines above the
lower cover to place the lines without any
problems and do not clamp the lines when
snapping-on the upper cover.
Connect the lines according to the labeling
(in the lower cover): a b E P M V1 V2 (from
the bottom to the top),
floor push button to a and E.
See wiring diagram on page 9
Place matching resistor
The video indoor station IVH3222 is not suitable
for the operation at the end of a strand ex
works. Switch in position OFF.
For the operation with further up streamed
video indoor stations slide the switch in posi-
tion ON.
Close the device
Set on the upper cover at both adjustment
increments of the lower cover (
1
).
Snap-on the upper cover below with slight
pressure (
2
)
Connect the handset
Plug the Western socket of the handset cord
into the socket at the underside of the tele-
phone.
floor push button
2