background image

 

07/2015 

TCS TürControlSysteme AG

 

Subject to technical changes. 

E-

Mail: [email protected]   •  www.tcsag.de

 

PI_ISW3130-uk 

2 A 

Short description 

 

   hands-free talking, manually controlled duplex communication can be activated 

  large, deteched, blue door release button 

  large speech button 

  light switch button 

  function key (fixed assignment with control function 8, alternate allocation can be acti-

vated: internal call, door release automatic, call diversion) 

  call OFF button for ring tone mute with optical indication 

  optical indication of door calls by LED (green) 

  optical display of a business while an established communication by LED (green) 

  sending the sender serial number in case of internal calls 

  ring tones can be adjusted by the user, selection of 13 ring tones with improved quality 

  voice volume and ring tone volume can be adjusted manually 

  acoustic call distinction between 2 front-door stations (with the configuration software 

configo™), flat door (floor door) and internal call  

  a parallel call can be activated (with the Service Device TCSK-01 or confi

go™) 

  audio privacy function and automatic call cut-OFF (after 2 min) 

  lower cover with plugged pined screw terminal can be pre-installed and can be 

equipped alternatively with the door telephone 

  optical and acoustic fault indication 

  can be functional extended due to mounting places for call relays, control for radio sig-

nal device 

  energy-efficient due to low stand-by consumption of only 0.025 W 

  automatic call acceptance after an internal call can be activated / deactivated 

 
 

Installation 

 

Mounting site 

The indoor station has to be installed in accord-
ance to a minimum distance to walls or other 
obstacles:  

  lateral space 5 cm and below 10 cm. 

 

 

Install the lower cover 

  For placing the connection cables without 

any problems, a flush-mount socket must be 
installed behind the device. 
Position the flush-mount socket below the 
cable conduit. 

  Install the lower cover with three screws. 

 
TIPP: Avoid tearing of the straps:  
 

For fixing the scraps do not use counter-head screws  

          Rather use flat washers! 

 

 

Summary of Contents for ISW3130

Page 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Product information Comfort indoor station for hands free talking ISW3130...

Page 2: ...the upper cover 7 Open the device 7 Installation of extended functions 8 Connect the lines 8 Connection lines 8 Wiring example 9 Connection diagram 2 wire technique 9 Connection diagram 3 wire techniq...

Page 3: ...separators between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sectio...

Page 4: ...OFF is activated flashes ring tone stopper is deactivated door release automatic or call diversion is activated flashes OFF ring tone stopper is activated door re lease automatic or call diversion is...

Page 5: ...rs like shown in price list dimensions in mm H 180 x W 100 x D 23 weight 185 g acceptable ambient temperature 5 40 C degree of protection IP30 input current stand by 2 wire operation I a 1 mA 3 wire o...

Page 6: ...oftware configo flat door floor door and internal call a parallel call can be activated with the Service Device TCSK 01 or configo audio privacy function and automatic call cut OFF after 2 min lower c...

Page 7: ...from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover Set on the upper cover at both adjustment increments of the lower cover 1 Snap on the upper cover...

Page 8: ...the indoor station with adhesive pads see also product information of each extended function Connecting the lines is implemented in analog to the ISW3030 see product information TRE1 EB 1 Connect the...

Page 9: ...2015 9 TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Wiring example Connection diagram 2 wire technique Connection diagram 3 wire techniq...

Page 10: ...check if it is connected to the a wire of the power supply and control unit Settings Preset times conversation time 2 min flashing period of the green LED if the voice channel is busy after establishi...

Page 11: ...control key until the required ring tone sounds The ring tone selected last is stored 3 Short press the call OFF button Or If no button is pressed for around 8 sec the device end the ring tone select...

Page 12: ...x unlimited communication time x reset to factory settings x If the floor door release function in the EEPROM has been activated and the door release automatic function via function key is switched on...

Page 13: ...other and put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistance cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 7...

Page 14: ...r not supplied connect the a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in st...

Page 15: ...Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a prog...

Page 16: ...ecting point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electri...

Reviews: