background image

07/2015 

 

TCS TürControlSysteme AG

 

Subject to technical changes. 

E-

Mail: [email protected]   •  www.tcsag.de

 

PI_ISW3130-uk                                2 A 

Scope of delivery 

 

1 x  comfort indoor station ISW3130: upper cover, lower cover 
 

product information 

 

instruction manual  

 
 

Safety instructions 

 

!

 

Attention! Mounting, installation, commissioning and repair of electronic devices have 
to be carried out only by qualified electricians. The current standard for the installation 
of door communication systems must be observed! 

 

When installing TCS:BUS systems, the general safety regulations for telecommunication 
systems according to VDE 0800 must be observed. Inter alia: 

  separated cabling of heavy and low current lines, 

  minimum distance of 10 cm for common cabling, 

  use of separators between heavy and low current lines in shared cable ducts, 

  use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter, 

  existing lines (modernisation) with deviating cross sections can be used in compliance 

with the loop resistance.  

Installation 

– protective measures  

!

 

With suitable requirements to protect against lightning, it hast to be ensured that a  
voltage of 32 V DC is not be exceeded at the connections a, b, P, E.  

 
 

Intended use 

 

  ISW3130 are indoor stations for hands-free talking for the object area. 

  They are suitable for the operation in TCS audio systems and combined audio / video 

systems. 

  They are suitable for surface-mount (installation via flush-mounted socket) or desktop 

mounting with desktop accessory ZIT3030-0010. 

 

Max. number of ISW3130 in 2-wire operation 

when using power supply 
and control unit 

max. number 

ISW3130 

 

BVS20 or  
NBV1000, 1 line 

20 

BVS100,  
distributed to 3 lines 

80 

VBVS05, 1 line 

30 

Summary of Contents for ISW3130

Page 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Product information Comfort indoor station for hands free talking ISW3130...

Page 2: ...the upper cover 7 Open the device 7 Installation of extended functions 8 Connect the lines 8 Connection lines 8 Wiring example 9 Connection diagram 2 wire technique 9 Connection diagram 3 wire techniq...

Page 3: ...separators between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sectio...

Page 4: ...OFF is activated flashes ring tone stopper is deactivated door release automatic or call diversion is activated flashes OFF ring tone stopper is activated door re lease automatic or call diversion is...

Page 5: ...rs like shown in price list dimensions in mm H 180 x W 100 x D 23 weight 185 g acceptable ambient temperature 5 40 C degree of protection IP30 input current stand by 2 wire operation I a 1 mA 3 wire o...

Page 6: ...oftware configo flat door floor door and internal call a parallel call can be activated with the Service Device TCSK 01 or configo audio privacy function and automatic call cut OFF after 2 min lower c...

Page 7: ...from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover Set on the upper cover at both adjustment increments of the lower cover 1 Snap on the upper cover...

Page 8: ...the indoor station with adhesive pads see also product information of each extended function Connecting the lines is implemented in analog to the ISW3030 see product information TRE1 EB 1 Connect the...

Page 9: ...2015 9 TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISW3130 uk 2 A Wiring example Connection diagram 2 wire technique Connection diagram 3 wire techniq...

Page 10: ...check if it is connected to the a wire of the power supply and control unit Settings Preset times conversation time 2 min flashing period of the green LED if the voice channel is busy after establishi...

Page 11: ...control key until the required ring tone sounds The ring tone selected last is stored 3 Short press the call OFF button Or If no button is pressed for around 8 sec the device end the ring tone select...

Page 12: ...x unlimited communication time x reset to factory settings x If the floor door release function in the EEPROM has been activated and the door release automatic function via function key is switched on...

Page 13: ...other and put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistance cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 7...

Page 14: ...r not supplied connect the a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in st...

Page 15: ...Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a prog...

Page 16: ...ecting point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electri...