Max. number of ISH3230 in 3-wire operation 

when using power supply 
and control unit 

max. number 

ISH3230 

 

NBV3210, 3 lines 

30 

VBVS05 (PSG02), 1 line 

10 

AS  front-door station 
VS  power suply and control unit 
IS  indoor station 
Note: The number of front-door stations which can be connected is limited. Details are described in respective product 
information!

 

 
 
 
 

Indication and operating elements 

 

 

handset 
 

  speaking to the door 

  end speaking 

 

 

call OFF button 

 

shortly press

: ring tone stopper 

 

press for 8 sec

: initiate ring tone selection 

 

 

indication call OFF 
(red) 
 

 

is ON

: call OFF is activated  

  fault indication: 

 

both LEDs flash 

  ring tone selection: both LEDs are ON 

 

control key  

  control function 8 

  ring tone selection internal call 

 

 

call indication 
(green) 

 

is ON

: call, speaking is activated  

 

blinks

 3 x: voice channel is busy 

  fault detection: 

 

both LEDs flash 

  ring tone selection: both LEDs are ON 

 

 

light button 

  switch lights 

  ring tone selection floor call (from the flat door) 

 

 

 

door release button 

  open the door 

  trigger light switch function (if the light switch function is 

activated at the front-door station) 

  ring tone selection door call from the front-door station 

 

 

volume control for 
voice output and 
ring tone 

adjustable in 8 steps: 

  when voice communication is established 

  when the handset is cradled (no voice communication) 

 

 
 
 
 

Summary of Contents for ISH3230

Page 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISH3230 uk 2A Product information Door telephone with announcement function ISH3230...

Page 2: ...Connect the lines 9 Connection lines 9 Wiring example 9 Connection diagram 3 wire technique 10 Replace an ISH1030 or TTS1 with an ISH3230 10 Commissioning 10 Settings 10 Preset times 10 Ring tone sele...

Page 3: ...deviating cross sections can be used in compliance with the loop resistance Installation protective measures With suitable requirements to protect against lightning it has to be ensured that a volt a...

Page 4: ...c initiate ring tone selection indication call OFF red is ON call OFF is activated fault indication both LEDs flash ring tone selection both LEDs are ON control key control function 8 ring tone select...

Page 5: ...plastics white dimensions in mm H 204 x w 100 x D 50 weight 340 g acceptable ambient temperature 5 40 C degree of protection IP30 input current in stand by I a 0 2 mA I P 1 mA max input current I Pmax...

Page 6: ...ll a parallel call can be activated via Service Device TCSK 01 or configo audio privacy function and automatic call cut off magnetic handset cradle pluggable handset cord lower cover with pined screw...

Page 7: ...es when snapping on the upper cover Connect the lines according to the labeling a b E P from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover Set on the...

Page 8: ...essure into this opening The upper cover can be removed at the underside 1 Lift the upper cover out of the two upper adjustment increments 2 Installation of extended functions TRE1 Radio transmitter b...

Page 9: ...nes Connecting lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Further wires have to be connected with auxiliar te...

Page 10: ...y an ISH3230 Commissioning Install the devices of the system voltage free and completely Check the a b and P wire against each other for short circuits Switch on the mains voltage Note If the floor pu...

Page 11: ...ol key until the required ring tone sounds The ring tone selected last will be stored 3 Shortly press the call OFF button Or If no button is pressed for around 8 sec the device ends the ring tone sele...

Page 12: ...gurations see product information Service Device TCSK 01 search telephones switch ON parallel call switch OFF parallel call Ser no the serial number of the indoor station which is to be configured ane...

Page 13: ...ach other and put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resitances cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28...

Page 14: ...r check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in stand by mode again Exchange an indoo...

Page 15: ...have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a programming lock The programming lock...

Page 16: ...for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for electricians Note ou...

Reviews: