Max. number of ISH3130 in 3-wire operation
when using power supply
and control unit
max. number
ISH3130
BVS20 or
NBV1000, 1 line
20
BVS100,
distributed to 3 lines
80
VBVS05, 1 line
90
BVS20 + NGV1011,
1 line
90
AS front-door station
VS power supply and control unit
IS indoor station
Note: The number of front-door stations which can be
connected is limited. Details are described in their
product information!
NGV1011,
3 lines
270
Indication and operating elements
handset
speaking to the door
end speaking
call OFF-button
shortly press
: ring tone stopper
press for 8 sec
: initiate ring tone selection
indication call OFF
(red)
is ON
: call OFF is activated
flashes
: ring tone stopper is deactivated, door release
automatic or call diversion is activated
flashing OFF
: ring tone stopper is activated, door re-
lease automatic or call diversion is activated
error indication:
both LEDs flashing
ring tone selection: both LEDs are ON
○
function key
control function 8,
alternate allocation can be activated: internal call, door
release automatic, call diversion
ring tone selection internal call
call indication
(green)
is ON
: call, speaking is activated
blinks
3 x: voice channel is busy
error indication:
both LEDs flashing
ring tone selection: both LEDs are ON
light button
switch lights
ring tone selection floor call (from the flat door)
door release button
open the door
trigger light switch function (if light switch function is
activated in the front-door station)
ring tone selection door call of the front-door station
volume control for
voice output and
ring tone
adjustable in 8 steps:
when voice communication is established
when the handset is cradled (no voice communication)