TCS ISH3130 Product Information Download Page 3

07/2012 

 

TCS TürControlSysteme AG

 

Subject to technical changes. 

E-Mail: [email protected]      www.tcsag.de

 

PI_ISH3130-uk.doc 

1A 

Scope of delivery 

 

1 x  indoor station ISH3130: upper cover, lower cover, handset with handset cord 
 

product information 

 

instruction manual  

 
 

Safety instructions 

 

!

 

Attention! Installation, mounting, commissioning and repair of electrical devices have 
to be carried out only by qualified electricians. The current standard for the installation 
of door communication systems must be observed! 

 

When installing TCS:BUS systems, the general safety regulations for telecommunication 
systems according to VDE 0800 must be observed. Inter alia: 

  separated cabling of heavy and low current lines, 
  minimum distance of 10 cm for common cabling, 
  use of separators between heavy and low current lines in shared cable ducts, 
  use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter, 
  existing lines (modernisation) with deviating cross sections can be used in compliance 

with the loop resistance.  

Installation 

– protective measures  

!

 

With suitable requirements to protect against lightning, it has to be ensured that a volt-
age of each 32 V DC is not to be exceeded at the connections a, b, P, E.  

 
 

Intended use 

 

  ISH3130 are door telephones for duplex communication with handset for the TCS:BUS.  
  They are suitable for the operation in TCS audio systems and combined audio/video 

systems in the object area. 

  They are suitable for surface-mount (installation via flush-mounted socket) or desktop 

mount with desktop accessory ZIT3030-0010. 
 

Max. number of ISH3130 in 2-wire operation 

when using power supply 
and control unit 

max. number 

ISH3130 

 

BVS20 or  
NBV1000, 1 line 

20 

BVS100,  
distributed to 3 lines 

80 

VBVS05, 1 line 

30 

Summary of Contents for ISH3130

Page 1: ...TCS T rControlSysteme AG Subject to technical changes E Mail hotline tcsag de www tcsag de PI_ISH3130 uk doc 1A Product information Door telephone with comfort functions ISH3130...

Page 2: ...7 Open the device 8 Build in extended functions 8 Connect the lines 9 Connecting lines 9 Wiring example 9 Connection diagram 2 wire technique 10 Connection diagram 3 wire technique 10 Replace an ISH1...

Page 3: ...tors between heavy and low current lines in shared cable ducts use of standard telecommunication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can...

Page 4: ...stopper is deactivated door release automatic or call diversion is activated flashing OFF ring tone stopper is activated door re lease automatic or call diversion is activated error indication both L...

Page 5: ...hite dimensions in mm H 204 x W 100 x D 50 weight 340 g acceptable ambient temperature 5 40 C degree of protection IP30 input current in stand by 2 wire operation I a 1 mA 3 wire operation I a 0 2 mA...

Page 6: ...2 front door stations via configuration software configo flat door floor door and internal call a parallel call can be activated via Service Device TCSK 01 or configo audio privacy function and automa...

Page 7: ...mp the lines when snapping on the upper cover Connect the lines according to the labeling a b E P from the button to the top floor push button at a E Wiring example see page 9 Snap on the upper cover...

Page 8: ...pressure into this opening The upper cover can be removed at the underside 1 Lift the upper cover out of the two upper adjustment increments 2 Installation of extended functions TRE1 radio transmitter...

Page 9: ...lines Connection lines acceptable cross section diameter 0 08 0 82 mm2 0 32 1 0 mm max number of wires per terminal contact each 2 x 0 8 mm 3 x 0 6 mm Further wires have to be connected with auxiliar...

Page 10: ...must be replaced with an ISH3130 Commissioning Install the devices of the system voltage free and completely Check the a b and P wire against each other for short circuits Switch on the main voltage...

Page 11: ...ds The ring tone selected last will be stored 2b select door ring tone of the floor door Press the light switch button until the required ring tone sounds The ring tone selected last will be stored 2c...

Page 12: ...ase of an internal call x change audio AS limit x block ring tone output x x block ring tone selection x unlimited communication time x reset to factory setting x If the floor door release function in...

Page 13: ...put it one sided on mass b wire in the power supply optional strand or star formed wiring Table loop resistances cable length in m cable diameter 0 6 mm 0 8 mm loop resistance in 10 1 28 0 71 20 2 55...

Page 14: ...e a wire or check power supply device is in stand by mode again button stucks press longer than 15 sec remove button at the device or loosen floor push but ton device is in stand by mode again Exchang...

Page 15: ...off a Not necessary if the bell buttons have not been programmed comp product information of the front door station 1 If there sounds a Progsperr tone instead the front door station is equipped with a...

Page 16: ...collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics Warranty We offer a simplified processing in case of warranty for el...

Reviews: