4
Scope of delivery
1 x CAI20x0-015x (top shell, wall adapter plate or tabletop device)
assembly instruction
product information
instruction manual
Safety instructions
General safety regulations
!
Assembly, installation, commissioning and repair of electronic devices
must be carried out by qualified electricians and in compliance with
current standards.
When working on main power connections of 230V AC, the general and
regional installation and safety regulations must be met. i.e. DIN VDE
0100
TCS:BUS system installations must be in compliance with the general
safety regulations for telecommunication systems according to VDE 0800.
Including:
separated cable routing of high and low voltage lines,
minimum distance of 10 cm in case of a common cable routing,
use of separators between high and low voltage lines within shared
cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm
diameter,
already existing lines (modernisation) with deviating cross-sections can
be used in compliance with the loop resistance.
Installation
– protective measures
!
Through suitable measures to protect against lightning, it has to be
ensured that a voltage of 32 V DC is not exceeded at each connec-
tion.