background image

 

02/2013

 

TCS TürControlSysteme AG, TCS Hotline Germany:  [email protected]

 

Subject to technical changes. 

FAX: +49 (0) 41 94/ 9 88 129 

 

PI_bre2eb_uk  1 A 

 

Manual programming 

Legend  

Press button until 

… 

    

 

LED blinks slowly 

 

Shortly press the button 

    

 

LED is ON 

 

Release the button 

    

 

further 

period until 

… 

    

 

|

 

 

 

Allocating the output to a bell button that is not programmed 

 
 
 
 
 

 

 shortly 

LED 

 press 

blinks 

 

    BRE2 

 
 
 

 

  shortly press, 
  LED  blinks 

1

 

 
 
 
 
 

 

  shortly press, 
  ring tone sounds 

 
 
 
 
 

 

 short 

LED 

 press 

is ON 

Programming mode

 of the 

system

 is switched ON 

 

Output is allocated to 
a bell button 

Programming mode 

of the 

system

 is switched OFF 

 

Allocating the output to a programmed bell button

 

 

 
 
 
 
 
 
 
 shortly 

LED 

 press 

blinks 

 
 
 BRE2 
 

 
 
 
 shortly press, 
 LED blinks 
 (for 30 s) 

 
 
 
 
 
 
 
press as long as Prog2 tone, light 
switch tone and ring tone sound 
at the front-door station, release 

 
 
 
 
 
 
 
 shortly 

LED 

 press 

is ON 

 

 

output is allocated to a bell button 

Programming mode

 of the 

system

 is switched OFF 

 

Delete the allocation to a bell button 

 
 
 
 

 

 shortly 

LED 

 press 

blinks 

 

 

 
 

 

  press until the delete  
  tone sounds, release 

 
 
 
 

 

 shortly 

LED 

 press 

is ON 

Programming mode

 of the 

system

 is 

switched ON 

  bell button deleted 

Programming mode 

of the 

system

 is switched OFF 

Allocate the output to a BUS action 

 

 BRE2 

 
 
 
 press until  

          release 

 the LED lights up 

 

 
 

 

 
  press the door opener or 
  press floor push-button or... 

 

 
 
 
 
 
 

shortly press, 

 

 

LED is OFF 

 

  execute required BUS action  
 

 Output is allocated to
 the BUS action. 

 

1)  The BRE2 returns into the operating mode after 30 s, the LED expires. If you want to cancel the programming at this 

point, switch off the programming mode of the system at the BVS. 

 

 

 

 

 

 

 

 

 
 
 

 

 

 

 

 

 

  

 

 

  

within 30 s 

Summary of Contents for BRE2-EB

Page 1: ...tors between heavy and low current lines within shared cable ducts use of standard communication lines e g J Y St Y with 0 8 mm diameter existing lines modernisation with deviating cross sections can be used in compliance with the loop resistance Attention The ingress of liquids or electronically conductive parts can cause short circuits fire or an electronic shock Thus provide water or other liqu...

Page 2: ...E2 EB is suitable to execute switching and detection functions in TCS BUS sys tems To be built in into flush mounted sockets Suitable for 3 wire connection a b and P 2 wire connection with max of 3 pieces BRE2 EB within the TCS BUS sys tem Short description Basic functions output potential free for switching functions to trigger the switch time by pressing bell buttons of any front door station fl...

Page 3: ...voice connection second serial number control functions and front door calls of 10 further serial numbers switch ON OFF function switch ON OVER function linkage of several relay switch functions setting a programming lock Function of the input as opener to create any TCS BUS protocol open the device s output Connecting the lines Connection lines per terminal TCS BUS input terminals 0 12 0 5 mm2 di...

Page 4: ... blinks for 30 s press as long as Prog2 tone light switch tone and ring tone sound at the front door station release shortly LED press is ON output is allocated to a bell button Programming mode of the system is switched OFF Delete the allocation to a bell button shortly LED press blinks press until the delete tone sounds release shortly LED press is ON Programming mode of the system is switched O...

Page 5: ... release the LED lights up press door opener or press floor push button or free BUS actions by entry via Service Device TCSK 01 press until the release LED lights up shortly LED OFF execute required BUS action input is allocated to BUS actions Reload factory setting2 switch time of the output 1 s input sends door release protocol AS 0 BRE2 press until release the LED is ON press until the LED rele...

Page 6: ...ormation on disposal The adjoining symbol shows that the device has to be disposed separately from domestic waste The material used are recycable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispose the parts of the packaging in collecting tanks for cardboard and paper resp plastics ...

Page 7: ...ct to technical changes FAX 49 0 41 94 9 88 129 PI_bre2eb_uk 1 A Warranty We offer a simplified processing in case of warranty for electricians Please note our conditions of sale and delivery download from www tcsag de down loads trade information Please contact the TCS HOTLINE ...

Page 8: ... Subject to technical changes FAX 49 0 41 94 9 88 129 PI_bre2eb_uk 1 A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS TürControlSysteme AG Geschwister Scholl Str 7 39307 Genthin Phone 49 0 3933 879910 FAX 49 0 3933 879911 www tcsag de ...

Reviews: