Programming options
manually
additional options with PC / con
figo™
Switch time of the output: 0.5 to 128 s
factory setting 1s
Switching functions of the output:
calling the
device‘s serial number
floor call, front-door door call and internal
call to the serial number
door release with serial number,
start of a voice connection and
control function of a serial number
Function of the input:
as closing contact to create any
TCS:BUS protocol
Switch time of the output:
up to 30 min or unlimited
pull-in delay up to 30 min
Switching functions of the output:
start of a voice connection at the front-door station
reset at the end of a voice connection
second serial number
control functions and front-door calls of 10 further serial
numbers
switch ON / OFF function, switch ON / OVER function
linkage of several relay switch functions
setting a programming lock
Function of the input:
as opener to create any TCS:BUS protocol
open the device’s output
Connecting the lines
Connection lines
per terminal
TCS:BUS, input terminals: 0.12 ... 0.5 mm
2
(diameter: 0.4 ... 0.8 mm) possible
output terminals:
0.5 ... 1.5 mm
2
(diameter: 0.8 ... 1.4 mm) possible
Connect the lines according to the following connection schemata
!
When using 3-wire technique, remove the jumper (see device overview)!
TCS:BUS terminals, input terminals
output terminal
Important note for commissioning
During the transport, the relay can be exposed to impacts. Thus, the contact can be
moved into working position (K1-K2 closed).
!
When starting the commissioning, connect the TCS:BUS to the relay and the
TCS:BUS to the power supply to move the contact into rest position.