Disassembly of 730 Air Eliminator Assembly
¡WARNING!
All internal pressure must be relieved to ZERO (0) pressure before beginning disassembly
of meter or components
1) Using a 1/2” wrench or socket, remove the cover screws from air eliminator cover plate.
2) Remove cover plate.
3) Remove valve plate, inspect and replace as needed.
1) To remove the air eliminator assembly, remove the four screws and washers attaching it to the
strainer assembly.
2) Using a flathead screwdriver, remove the screws attaching reed valves to air eliminator housing.
3) Remove the two screws on the diffuser screen.
4) Slide out diffuser shaft assembly.
5) Remove the two screws attaching reed valve to the float assembly. Inspect and replace reed valves
as needed.