UV100A ULTRAVIOLET AIR TREATMENT SYSTEM

7

69-1659

6.

Continue lightly pushing in on the lamp while rotating it slowly counterclockwise. 

This should cause the lamp to drop into the bottom of the lamp well.

7.

Rotate the lamp clockwise until it snaps into place with the lamp light indicator 

aligned with the raised button on the unit cover.

WARNING

UV Light Hazard.

Harmful to bare skin and eyes.

Can cause temporary or permanent loss of vision.

Never look at the lamps while illuminated. 

Only view illumination by way of the light indicator located on the lamp knob.

To prevent exposure to ultraviolet light, disconnect power to the ultraviolet air 

treatment system before servicing any part of the heating/air conditioning 

system.

8.

Plug your ultraviolet air treatment system cord into the nearby 120 Vac electrical 

outlet.

9.

Verify that your ultraviolet lamp(s) are operating 

only by viewing through 

the 

lamp light indicator on the lamp knob.

 Never look directly at your lamp(s) while 

illuminated

.

10.

Reconnect the power to your HVAC system.

Table 1.  Replacing Your Lamp(s).

Unit Description

Replacement Lamps

Wattage

UV100A1085 Coil Irradiation Unit

UC100A1054

36W

Summary of Contents for 69-1659 UV100A

Page 1: ...U S Registered Trademark Copyright 2002 All Rights Reserved 69 1659 UV100A Ultraviolet Air Treatment System OWNER S GUIDE...

Page 2: ...ing HVAC system when you combine your Ultraviolet Air Treatment System with a high efficiency air filtration system that includes an electronic air cleaner Talk to your installer about adding an elect...

Page 3: ...in location that allows ultraviolet light to be seen after installation Do not attempt to bypass the duct mount switch Do not attempt to open housing unit is sealed to prevent ultraviolet light exposu...

Page 4: ...into lamp base Wear protective gloves when handling lamp s Cleaning Your Lamps Every Three Months Quarterly MERCURY NOTICE This device contains mercury in the sealed ultraviolet lamp s Do not place yo...

Page 5: ...reatment system cord from the electrical outlet and allow the lamps to cool for at least 15 minutes 3 Rotate your lamp knob counterclockwise and gently pull the lamp knob to remove the lamp s 4 Holdin...

Page 6: ...irectly at your lamps while illumi nated 10 Reconnect the power to your HVAC system CAUTION UV Lamp Burn Hazard Harmful to bare skin Can cause severe burns Disconnect power 15 minutes before removing...

Page 7: ...nated Only view illumination by way of the light indicator located on the lamp knob To prevent exposure to ultraviolet light disconnect power to the ultraviolet air treatment system before servicing a...

Page 8: ...the possession of a consumer UPG s sole responsibility shall be to repair or replace the product within the terms stated above UPG SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY...

Reviews: