        Communicating Thermostats

        Communicating Thermostats

SZ1009

Conventional Heating & Cooling 

Thermostats with Heat Pump Mode

Product Manual          

Description                             

The SZ1009 is a microprocessor-based programmable 

thermostats designed for conventional heating and cool-

ing applications with optional heat pump mode. The 

SZ1009 features a 7-day time clock. 

Features                                 

•   Stand-alone or network operation

•   Adjustable delay on power-up and start-up for soft 

starts

•   P+I control option

•  Smart Recovery

•   No battery backup required

•   Built-in HVAC equipment protection

•   32 character LCD display

•   6 status LEDs

•   Remote room sensing capability

•   User setpoint adjustment limits

•   Local and remote override capability 

•   System and fan switching with access lockouts

•   Equipment monitoring inputs and indication

•   External time clock input 

•   Access to programming or schedule may be locked 

out or limited with the use of an access code

•  Fahrenheit or Celsius temperature display

•  Convertible to heat pump mode in programming

Contents                                  

Description

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Features

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Wiring

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Setup

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Programming

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Setting Clock & Schedule

. . . . . . . . . . . . . . . . . . . . . . . 6

Program Options & Operating Features

. . . . . . . . . . . . 7

Checkout & Troubleshooting

  . . . . . . . . . . . . . . . . . . . .

10

LED Description

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

User’s Guide

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Mounting                                 

The SZ1009 is designed for wall mounting using two 

#6-32 machine screws sheet metal screws, either over 

a horizontally installed 2” x 4” junction box, or directly to 

block or drywall. 

For best results, the thermostat should be mounted on 

an interior wall which reflects normal room environment, 

at a height of approximately five feet from the floor. 

Avoid areas exposed to direct sunlight, unusual heat 

or cool sources, open doors and windows, unventilated 

locations and hot or cold air from diffusers.
If using a remote room sensor, it should be mounted in 

the manner described above.  The thermostat may then 

be mounted in an area which is accessible for adjusting 

its settings. 

Caution

:  Remove power from thermostat 

prior to mounting.

Summary of Contents for SZ1009

Page 1: ...ing or schedule may be locked out or limited with the use of an access code Fahrenheit or Celsius temperature display Convertible to heat pump mode in programming Contents Description 1 Features 1 Mou...

Page 2: ...designations for wir ing See diagram below REMOTE TEMPERATURE SENSOR WIRING Use 18 AWG shielded twisted pair grounded at the sen sor mounting location Sensor wiring runs of up to 250 feet are attainab...

Page 3: ...outdoor air sensor only Using remote room sensor with both discharge and outdoor air sensors KEYPAD ACCESS The dipswitches in the thermostat cover shown above must be set in order to lock the user out...

Page 4: ...K 9 6K and 19 2K Display Type Screen Choose between FAHRENHEIT and CELSIUS for tem perature indication Controller Type Screen Choose Conventional or Heat Pump mode Unit will reset the screen will mome...

Page 5: ...cool stage 1 Control Mode Screen Enter if you want to control by temperature only P or add a time factor P I Discharge Air Sensor Function Screen Choose whether or not you are using a discharge air s...

Page 6: ...n on programming through the PC consult your TCS soft ware manual SETTING CLOCK SCHEDULE THROUGH THE KEYPAD To access the clock and schedule screens press the clock setup button To make changes use th...

Page 7: ...xternal time clock OVERRIDE A timed override is available using the button on the face of the thermostat or through momentary contacts wired into the OVR terminal The amount of time the unit will be o...

Page 8: ...G LOCKOUT TEMP all cooling stages will be locked out and will remain locked out until the outdoor air temperature rises 2 above the lockout temperature If the outdoor temperature rises above the HEATI...

Page 9: ...HECK DI2 NO Dry contact switch Any type DI2 SERVICE OFF or ON for monitoring and indication DI2 Monitor with NO OK YES shifts setpoint by Dry contact switch setpoint shift DI2 OPEN or CLOSED programme...

Page 10: ...e warmer button until the cooling setpoint is greater than the current temperature by one degree The cooling stage s will sequence off The fan will turn off 2 minutes after the last cooling stage 10 G...

Page 11: ...the service status button simultaneously Service LED is On If the service LED is on it may be for monitoring purposes or it may indicate a critical problem The first monitoring screen which is used t...

Page 12: ...put are closed PROGRAM DATA This LED will be lit when the thermostat is within the pro gramming or clock setup menus It will blink when the unit is being accessed by a PC Additional monitoring is avai...

Reviews: