TCL U-MATCH-R32 SERIES DC INVERTER AIR CONDITIONERS SERVICE MANUAL
205
FA
Compressor phase current detection fault
43
Hardware Error
Fb
Cooling and heating overload protection limit
frequency reduction
44
Remote control display
adjustment
FC
High power protection limit/ frequency reduction
45
Remote control display
adjustment
FE
Module current ( compressor phase current)
protection limit/ frequency reduction
46
Remote control display
adjustment
FF
Module temperature protection limit/ frequency
reduction
47
Remote control display
adjustment
FH
Drive protection limit/ frequency
reduction
48
Remote control display
adjustment
FP
Anti condensation protection limit/
frequency reduction
49
Remote control display
adjustment
FU
Anti freezing protection limit/ frequency reduction
50
Remote control display
adjustment
Fj
Exhaust protection limit/ frequency
reduction
51
Remote control display
adjustment
Fn
External AC current protection limit/
frequency reduction
52
Remote control display
adjustment
Fy
Fluorine deficiency protection
53
Others Error
H1
High pressure switch malfunction
54
Hardware Erro
H2
Low pressure switch malfunction
55
Hardware Erro
bf
TVOC sensor failure
56
Remote control display
adjustment
bc
PM2.5 sensor failure
57
Remote control display
adjustment
b j
Humidity sensor failure
58
Remote control display
adjustment
bE
CO2 sensor malfunction
59
Hardware Erro
bd
Fresh air fan failure
60
Hardware Erro
d4
Water full protection
61
Others Erro
d5
Access control protection
62
Hardware Erro