TCL Air Conditioner Service Manual
31
2.3 Outdoor Unit Installation
2.3.1 Service Space for Outdoor Unit
NOTE:
The minimum distance between the outdoor unit and walls described in the installation
guide does not apply to airtight rooms. Be sure to keep the unit unobstructed In at least two of the three
directions (Front, Left, Right). (As shown on the right)
2.3.2 Install the Unit
Bolt pitch refers to the part of 3.4.3
Since the gravity center of the unit is not at its physical center, so please be careful when lifting it
with a sling.
Never hold the inlet of the outdoor unit to prevent it from deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45
°
, and do not lay it sidelong.
Make concrete foundation according to the specifications of the outdoor units.
Fasten the feet of this unit with bolts firmly to prevent it from collapsing in case of earthquake or strong
wind.
2.3.3 Outdoor Unit Condensed Water Drainage (Optional)
The condensed water and the ice formed in the outdoor unit during heating operation can be
drained away throughthe drain pipe
1. Fasten the drain port in the 25mm hole placed in the part of the unit as shown in the picture.
2. Connect the drain port and the drain pipe. Pay attention that water is drained in a suitable place.