TCL TAC-09CHSA/GI Service Manual Download Page 18

TCL Air Conditioner Service Manual 

18

 

PART LIST 

Outdoor unit 

Model: TAC-12CHSA/GI 

No. 

Part No. 

Part Name 

Q’ty 

Remark 

1 1080050026 

Grille 

 

2 1080050011 

Top 

cover 

 

3 1110050069 

Condenser 

 

1080050004 

Outdoor motor supporter 

 

5 1170040058 

Outdoor 

motor 

 

6 1070030016 

Propeller 

fan 

 

1080050001 

Left grille supporter 

 

8 1080050007 

Left 

grille 

 

1080050009 Front 

plate 2 

 

10 1080320112 

Fan 

guard 

 

11 1100060052 

Compressor 

and 

accessories 

 

12 1140020004 

Sound 

arrester 

420mm*240mm*12mm

13 1120500226 

4-way 

valve 

 

14 

1120321531 

Three-way valve connecting pipe 

 

15 1120321529 

Suction 

pipe 

 

16 1120321530 

Discharge 

pipe 

 

17 

1120321532 

Condenser connecting pipe 

 

18 1120321525 

Capillary 

assembly 

 

19 1140020011 

Sound 

arrester

750*350*8

 1 

 

20 

1080050002 Right 

plate 1 

 

21 1080050002 

Valve 

supporter 

 

22 1120120021 

Two-way 

valve 

 

23 1210250121 

Base 

 

24 1120130032 

Three-way 

valve 

 

25 1170190003 

Inductor 

 

26 

1170200061 

Pipe Temp. sensor and outdoor Temp. sensor

 

27 

1080320001 Clapboard 1 

 

28 1170230006 

Discharge 

Temp. 

sensor 

 

29 1070320202 

Sensor 

holder(

φ

10) 1 

30 1070040007 

Cable 

clamp 

31 1170200061 

Terminal 

32 

1170100010 

Fan motor capacitor 

Not shown in explosion 

view 

33 1070320207 

Electrical 

box 

 

 

34 

1090321110 Power 

source 

board    

35 1090321113 

Power 

module 

 

 

36 1090320003 

PFC 

board 

 

 

37 1170330001 

Radiator 

 

 

 

Summary of Contents for TAC-09CHSA/GI

Page 1: ...PE AIR CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 4 WIRING DIAGRAM 11 5 EXPLOSION VIEW 12 6 PARTS LIST 13 Models TAC 09CHSA GI TAC 12CHSA GI TCL SERVI...

Page 2: ...formation nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or improvement without any prior n...

Page 3: ...H x D Outdoor mm 760 560 260 760 560 260 Indoor kg 8 5 8 5 Outdoor kg 30 34 Packing dimensions Indoor mm 883 325 271 883 325 273 W x H x D Outdoor mm 863 598 381 863 598 383 Indoor kg 10 5 10 5 Outdoo...

Page 4: ...ler 6 2 5 3 7 1 1 1 TCL Air Conditioner Service Manual Operation Details Remote Control The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer Each time af...

Page 5: ...is overload controller shut down the unit immediately and show error code 6 Compressor abnormity protection When compressor start on or in the process of running if there is no feedback to controller...

Page 6: ...or will run automatically 3 Auto fan control in cooling mode In cooling mode include cooling in I feel mode fan speed is determined by t as the following diagram 1 5 1 0 3 0 3 5 t come down high fan t...

Page 7: ...ocess of defrosting 4 Defrosting Defrosting is controlled by the microprocessor When one of the following conditions is satisfied unit will come into defrosting a Outdoor heat exchanger Temperature OP...

Page 8: ...later z When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 2hour later z After the System operates in SLEEP mode for 8 hours it will stop auto...

Page 9: ...of the error list z Protection display function can be selected in hardware and the default don t display z To insure of in and out communist is credibility the failures relate to outdoor unit will r...

Page 10: ...tdoor power board when compressor is running it is normally light when no feedback of signal to power board from compressor it will wink by lighting 1s and going out 1s If failures happened it will li...

Page 11: ...TCL Air Conditioner Service Manual Wiring diagram Model TAC 09CHSA GI TAC 12CHSA GI Indoor unit Outdoor Unit 11...

Page 12: ...TCL Air Conditioner Service Manual EXPLOSION VIEW Indoor unit Model TAC 09CHSA GI TAC 12CHSA GI 12...

Page 13: ...filter 2 13 1070321113 panel 1 14 1070321107 Ornament strip 1 15 1170120045 Power supply cord 1 16 1070320104 vane 1 17 1070110008 Drainage hose 1 18 1070040004 Cable clamp 1 19 1170200042 Terminal 1...

Page 14: ...r filter 2 13 1070321113 panel 1 14 1070321107 Ornament strip 1 15 1170120045 Power supply cord 1 16 1070320104 vane 1 17 1070110008 Drainage hose 1 18 1070040004 Cable clamp 1 19 1170200042 Terminal...

Page 15: ...TCL Air Conditioner Service Manual EXPLOSION VIEW Outdoor unit Model TAC 09CHSA GI TAC 12CHSA GI 15...

Page 16: ...necting pipe 1 15 1120250425 Suction pipe 1 16 1120250426 Discharge pipe 1 17 1120250428 Condenser connecting pipe 1 18 1120250615 Capillary assembly 1 19 1140020011 Sound arrester 1 750 350 8 20 1080...

Page 17: ...nual 17 PART LIST Outdoor unit Model TAC 09CHSA GI No Part No Part Name Q ty Remark 38 1190070020 Base carton 1 39 1190700302 Cabinet carton 1 40 1190070022 Base foaming 1 41 1190070021 Cover foaming...

Page 18: ...pipe 1 15 1120321529 Suction pipe 1 16 1120321530 Discharge pipe 1 17 1120321532 Condenser connecting pipe 1 18 1120321525 Capillary assembly 1 19 1140020011 Sound arrester 750 350 8 1 20 1080050002 R...

Page 19: ...nual 19 PART LIST Outdoor unit Model TAC 12CHSA GI No Part No Part Name Q ty Remark 38 1190070020 Base carton 1 39 1190700302 Cabinet carton 1 40 1190070022 Base foaming 1 41 1190070021 Cover foaming...

Reviews: