Factory Alignment Specification of normal SIACP
Page 11 of 12
Appendix
n
“How
to
download
FLASH
SW”
Prepare MTK SW tool for update.
1. Connect the PC to the serial connector on board using a special serial device (USB or
COMx).
2. Provide the a correct voltage to the board
3. Start “
MTKTOOL
.
exe
” application under MTKxx folder, and set the parameters as below
picture(notice:select MT536X chassiss):
4. Press “Browse” button to select the corresponding SW bin file to upload
5. Press “Upgrade” button then press “NOR” button to start downloading the SW and wait the
gauge displayed “100%” that means the SW has been successfully downloaded.
In the meanwhile, all operations such erasing flash and so… are parsed into the debug
window script.
6. Once the SW is downloaded, switch-off/on the chassis board and wait few seconds for
eeprom update.
Appendix
o
“How
to
upgrade
FLASH
SW
from
USB”
Upgrade with loader:
1. Save the new software file(*.pkg) in the root directory of USB, and modify it’s name as
upgrade.pkg.
2. Plug in the USB when TV set is “power off” or “standby” (TV set should be on “standby” status
if using a touch sensing keyboard).
3. Press down “power” key on keyboard, power on if it is on “power off” status , release the
“power” key 2~5 second later , the LED on IR board will flash after upgrade begin, the TV set
will start up if upgrade succeed.The LED is on but no flash if upgrade fail,check the set and