Factory Alignment Specification of normal SIACP
Page 8 of 12
Each panel has it’s own colour coordinates, Please refer to the following table.
㪛㫐㫅㪸㫄㫀㪺㪆㪎㪇㩼㩷㪮
L32V6200/L32E5200 L42E5200F/L42V6200F
C32E320/L32P60
C42E320F/L42P60F
x
y
x
y
x
y
x
y
Normal
0.275
0.310
0.275
0.290
0.280
0.290
0.280
0.290
Cool
0.265
0.285
0.265
0.290
0.270
0.280
0.270
0.280
Warm 0.305
0.330
0.305
0.330
0.312
0.330
0.320
0.320
Expected Targets and Tolerances
The measured parameters should be “x, y” coordinates.
The White Balance alignment should be performed using a contact less analyzer (ei: Minolta
CA-210). The analyzer may not touch the screen surface, and measurement must be performed in a
dark environment keeping the probe(s) at 90+/-2° from the panel.
The result should measure up the relevant spec.
2.4 High Pot. and Insulating Resistance Tests
At the end of the process, a High Pot. and an Insulating Resistance tests are required for
matching Safety Electrical requirements (ei: xxxx)
High Voltage Withstanding requirements
- “Voltage”
Ö
3500 VAC
- “Max Leakage Current”
Ö
10 mA
- “Test Time”
Ö
5 sec
Insulating Resistance requirements
- “Voltage”
Ö
DC500V
- “Threshold Min”
Ö
4M
¡
- “Test Time”
Ö
3 sec
3.Factory
default
settings
Do the “Reset shop” before packing.The detail of reset shop follow OOB setting.
“Factory Menu” Definition
1)
ˊ
Hotkey
Item
Sub-item
Value
Note
Hotkey
Off/On
OFF
ġ
hotkey is invalid
ON
ġ
hotkey(Return key) is availability
2)
ˊ
Burning Mode