background image

4

Note: Each mode and relevant function will be further specified in following pages. 

SLEEP

FAN

TIMER

SWING

ON/OFF

MODE

MID

SWING

AUTO

DRY
FAN
HEAT

COOL

FEEL

SLEEP TIMER ON

HIGH

LOW

TMIER OFF

The remote controller transmits signals  to the system.

Remote controller

1

2

4

3

5

6

7

8

8

4

MODE  button

FAN SPEED control button

UP button (TOO COOL button)

DOWN button (TOO WARM button) 

ON/OFF button

SLEEP  button

VANE control button

 TIMER button

Used to select the type of operation mode:  Feel, 
Cooling, Dry, Fan and Heating(Only for Heat Pump).
 

Used to select the indoor fan motor speed:
 Auto, High, Mid and Low. 

Used to increase the set room temperature

 and time.

Used to decrease the set room temperature
and time. 

Used to set or cancel sleep mode operation. 

Used to start and stop operation 
when pressed.  

Used to adjust airflow direction.

Used to select TIMER operation.

Remote controller

6

2

5

3

7

1

1

1

TCL Air Conditioner Service Manual

Operation Details

Remote Control

The remote  controller is  not  preset  as Cooling  Only

  

Air Conditioner  or Heat  Pump by  manufacturer.

Each time after the remote controller replace batteries or is energized, the 

 

arrowhead will flash on the front of 

Heat

or 

Cool

on LCD of the remote controller.

User can preset the remote controller type depending on the air conditioner type you have purchased as 
follows:
Press any button when the arrowhead flashes on the front o

Cool

, Cooling Only is 

 

set.

Press any button when the arrowhead flashes on the front of 

 Heat

, Heat Pump is set.

If you do

n

t press

 

 any button within 10 seconds, the remote controller is preset as Heat Pump automatically.

Note :

If the air conditioner you purchased is a Cooling Only one, but you preset 

 

the remote controller as Heat Pump, it 

doesn

t  matter. But if the air conditioner you purchased is a

 

 Heat Pump one, and you preset the remote 

controller  as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.

Summary of Contents for KFTHP-09

Page 1: ...CONDITIONERS CONTENTS 1 IMPORTANT NOTICE 2 2 TECHNICAL SPECIFICATION 3 3 OPERATION DETAILS 4 4 ELECTRICAL SCHEMATIC DIAGRAM 13 5 EXPLOSION VIEW 16 6 PARTS LIST 22 Models KFTHP 12 KFTHP 18 KFTHP 24 TCL...

Page 2: ...or the interpretation of this information nor can it assume any liability in connection with its use The information specifications and parameter are subject to change due to technical modification or...

Page 3: ...i m 3 h 700 730 950 1000 1400 1450 Indoor fan type Cross flow Cross flow Cross flow Cooling rpm 1330 1150 950 1550 1230 1110 1550 1230 1110 Heating rpm 1330 1150 950 1550 1230 1110 1550 1230 1110 Dry...

Page 4: ...controller 6 2 5 3 7 1 1 1 TCL Air Conditioner Service Manual Operation Details Remote Control The remote controller is not preset as Cooling Only Air Conditioner or Heat Pump by manufacturer Each tim...

Page 5: ...ditioner Service Manual REMOTE CONTROLLER The four types of remote controller is as follow GYKQ 05 GYKQ 10e optional GYKQ 11e optional GYKQ 12e optional Note The function of remote controller above is...

Page 6: ...compressor Outdoor fan OFF when the indoor pipe temperature is Outdoor fan ON when the indoor pipe temperature is 118 4 Compressor OFF when the indoor pipe temperature is Compressor ON when the indoor...

Page 7: ...e is selected without setting temperature the system will set the temperature at automatically with the AUTO FAN speed 2 When selecting the HEATING mode operation the system will operate according to...

Page 8: ...of the IPT is less than for 2 minutes When the defrosting operation time on this condition exceeds 8 minutes it will terminate C After the compressor operates continuously for 20 minutes and the IPT...

Page 9: ...de the set temperature will be raised by 1 1 hour later and by 2 hour later When selecting HEATING operation with SLEEP mode the set temperature will be dropped by 1 1 hour later and 2 hour later Afte...

Page 10: ...andard position and then set to the desired angle The positioning is decided as follows When the ON OFF button is pressed When the vane control is change from AUTO to MANUAL When the SWING is finished...

Page 11: ...pressed or a button on the remote controller is pressed and normal operation will start NOTE Do not press the EMERGEMCY Operation switch during normal operation 14 AUTO RESTART Function Option 1 When...

Page 12: ...gnal of remoter controller except the signal of shut off When the system checks the voltage is 220V and the delay control is finished it operates at normal again When the indoor fan motor is failure t...

Page 13: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 12 13...

Page 14: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 18 14...

Page 15: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 24 15...

Page 16: ...TCL Air Conditioner Service Manual 16 EXPLOSION VIEW MODEL KFTHP 12 INDOOR UNIT...

Page 17: ...TCL Air Conditioner Service Manual EXPLOSION VIEW MODEL KFTHP 18 INDOOR UNIT 17 18 16 15 14 13 12 11 9 10 7 8 6 20 19 23 21 22 24 25 28 27 26 5 4 3 2 1 17...

Page 18: ...TCL Air Conditioner Service Manual EXPLOSION VIEW MODEL KFTHP 24 INDOOR UNIT 17 18 16 15 14 13 12 11 9 10 7 8 6 20 19 23 21 22 24 25 27 26 28 29 30 31 5 4 3 2 1 18...

Page 19: ...TCL Air Conditioner Service Manual EXPLOSION VIEW MODEL KFTHP 12 OUTDOOR UNIT 16 27 26 25 24 23 22 21 20 19 18 17 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 19...

Page 20: ...TCL Air Conditioner Service Manual EXPLOSION VIEW MODEL KFTHP 18 OUTDOOR UNIT 24 16 28 27 26 25 23 22 21 20 19 18 17 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20...

Page 21: ...TCL Air Conditioner Service Manual EXPLOSION VIEW MODEL KFTHP 24 OUTDOOR UNIT 24 16 28 27 26 25 23 22 21 20 19 18 17 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 21...

Page 22: ...e Clamp Base 1 1070040006 Cable Clamp Cover 1 15 1110050903 Evaporator 1 16 1070350137 Water Drainage Assembly 12 17 1070350140 Vane 1 18 1070110011 Drainage Hose 1 19 1070350155 Evaporator Fastness C...

Page 23: ...Assembly 1 15 1173090107 Transformer 1 16 1070500692 Front Panel 1 17 1070500502 Display PCB Cover 1 18 1091990054 Heater 1 19 1073090126 Display PCB Box 1 20 1090500501 Display PCB 1 21 1073090108 V...

Page 24: ...ertical Vane 2 13 1070110012 Drainage Hose 1 14 1170230001 Indoor Sensor Assembly 1 15 1173090107 Transformer 1 16 1070850257 Front Panel 1 17 1070850148 Display PCB Cover 1 18 1091990055 Heater 1 19...

Page 25: ...alve 1 14 1120130036 Three way Valve 1 15 1081990107 Electrical Box Cover 1 16 1080050002 Right Plate 1 17 1070040001 Cable Clamp 6 1 1070040003 Cable Clamp 8 1 1070040008 Cable Clamp 10 1 18 11719900...

Page 26: ...021 Two way Valve 1 14 1120130032 Three way Valve 1 15 1081990107 Electrical Box Cover 1 16 1081990039 Right Plate 1 17 1074060118 Cable Clamp 1 18 1171990049 Terminal 1 19 1170100026 Compressor Capac...

Page 27: ...r 1 13 1120120037 Two way Valve 1 14 1120130047 Three way Valve 1 15 1081990107 Electrical Box Cover 1 16 1080050043 Right Plate 1 17 1074060118 Cable Clamp 1 18 1171990049 Terminal 1 19 1170100007 Co...