TCL Air Conditioner Service Manual
Technical Specifications
Model
No.
KFTHP-12 KFTHP-18 KFTHP-24
Type
Heating pump
Heating pump
Heating pump
Control
type
Remote Remote Remote
Rated
cooling
capacity
Btu/h
12500 18000 24000
Rated heating capacity
Btu
/h
12000 17
3
00 23500
SEER
Btu/W.h
13.1 13.3 13.0
HSPF
Btu/W.h
8.8 8.1 8.5
Moisture
removal
Liters/h
1.2 1.5 2.0
High
dB(A)
42 56 57
Med.
dB(A)
40 54 55
Indoor noise level at
cooling
Low
dB(A)
38 50 52
Outdoor sound power level
dB(A)
52
54
59
Electrical Data
Power supply
60Hz/1P
Voltage
range
V
208-230V 208-230V 208-230V
Cooling
A
4.6 6.7 9.7
Rated current
Heating
A
4.6 6.4 9.7
Cooling
W 1000 1550 2050
Rated input
Heating
W 1000 1500 2050
Refrigerating System
Refrigerant/Charge
Gram
R410A R410A R410A
Type
Rotary Rotary Rotary
Model ------------------
-----------------
--------------
LRA A
------
-------
---------------
Compressor
MFG -----------------
-----------------
---------------
Expansion device
Capillary tube
Defrosting system
Microcomputer controlled reverse system
Fan System
Indoor air circulation/Hi
m
3
/h 700/730 950/1000 1400/1450
Indoor fan type
Cross flow
Cross flow
Cross flow
Cooling
rpm 1330/1150/950
1550/1230/1110
1550/1230/1110
Heating
rpm 1330/1150/950
1550/1230/1110
1550/1230/1110
Dry rpm
1080
1100
1100
Motor rotating speed
H/M/L
Sleep rpm
1080
1100
1100
Indoor fan motor output
W
20
60
54
Outdoor air circulation
m3/h
---
---
----
Outdoor fan type
Propeller fan
Propeller fan
Propeller fan
Outdoor fan speed
rpm
860
750
860
Outdoor fan motor output
W
31
76
1
5
0
Connections
Refrigerant coupling
Flare type
Gas Inches 3/8''
(9.52)
1/2'' (12.7)
5/8'' (15.88)
Connecting pipe
Liquid Inches 1/4''
(6.35)
1/4'' (6.35)
3/8'' (9.52)
Connecting wiring
Size
×
Core
number
3
×
1.5; 2
×
0.75
3
×
1.5; 2
×
0.75
2
×
0.2(2
×
0.33)
3
×
2.5
Drainage pipe
O.D 16mm
Others
Suitable
area
m2
15~23 20~35 30~50
Indoor mm
898
×
280
×
202
1033
×
313
×
202
1250
×
325
×
245
Net dimensions
(W x H x D)
Outdoor mm
760
×
552
×
256
902
×
660
×
307
900
×
800
×
360
Indoor kg
11
14
22
Net weight
Outdoor
kg
34 47 59
Indoor mm
995
×
365
×
298
1103
×
395
×
292
1317
×
422
×
338
Packing dimensions
(W x H x D)
Outdoor mm
863
×
605
×
376
1027
×
705
×
433
1031
×
925
×
447
Indoor
kg
14 17 26
Gross weight
Outdoor
kg
37 54 65
Loading
Capacity
40’/40’HC
------ ------ ------
3
Summary of Contents for KFTHP-09
Page 13: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 12 13...
Page 14: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 18 14...
Page 15: ...TCL Air Conditioner Service Manual ELECTRICAL SCHEMATIC DIAGRAM MODEL KFTHP 24 15...
Page 16: ...TCL Air Conditioner Service Manual 16 EXPLOSION VIEW MODEL KFTHP 12 INDOOR UNIT...