sunlight; We will not be liable for problems caused by installation in an unsuitable
location.
The appliance must be installed 2 - 3m above floor level.
The unit must be mounted with an earth wire with the specified section area and securely
mounted; do not connect the earth wire with the earth wire of gas pipelines, water
pipelines, arrester conductor or phone systems so as not to cause an electric shock risk.
The main power supply switch of unit should be placed out of reach of children so as not
to cause a hazard.
INDOOR UNIT POSITION
The air inlet and outlet vent should be away from any obstruction, ensuring that there is a good
airflow through the whole air-conditioned space. Select a position where the condensing water
can be easily drained out, and the indoor unit can be easily connected to outdoor unit.
The ceiling
where the unit is fixed should be
strong enough to withstand the full weight and vibration of the
unit. The unit should be accessible for service and maintenance. The height of the installed unit
should be more than 200cm from the floor. The air conditioner must not be installed in a wet
environment such as a bathroom, shower or swimming pool etc.
OUTDOOR UNIT POSITION
A convenient position, dry and well ventilated, outside of direct sunlight or strong winds, which is
not on a flood line and where noise and airflow does not cause interference or inconvenience.
Select a location where there are no obstructions to the inlet and outlet vents. The location
should be able to withstand the full weight and vibration of the outdoor unit and permit safe
installation.
Make sure that the outdoor unit is installed in compliance with the installation dimension diagram
with easy maintenance access. Select a place where it is out of reach of children. Do not block
utilities access or fire escapes.
The external unit must be lifted and put in place by two people.
NOTES:
1.
Only use a power supply with the correct ratings, making sure the correct sized power cables
are used
2.
The appliance shall be installed in accordance with standard wiring regulations by qualified
personnel
3.
Only replace fuses according to their printed rating or corresponding pcb boards.